Late dislodgement of left bundle branch pacing lead and successful extraction
- 10 July 2021
- journal article
- case report
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 32 (8) , 2346-2349
Abstract
A 61‐years‐old male underwent left bundle branch pacing for nonischemic dilated cardiomyopathy with recurrent heart failure. Left bundle branch pacing (LBBP) resulted in reduction in QRS duration along with improvement in left ventricular ejection fraction (LVEF) to 64% during follow‐up. Two years after implantation he had recurrence of symptoms along with decline in LVEF to 51%. Late lead dislodgement was diagnosed and re‐do LBBP was planned. The lead was extracted en‐masse without complication and a new 3830 lead was positioned deep inside the proximal septum to capture the left bundle. Postprocedure echocardiography showed no ventricular septal defect or damage to tricuspid leaflet.Keywords
This publication has 7 references indexed in Scilit:
- Intermediate-term performance and safety of His-bundle pacing leads: A single-center experienceHeart Rhythm, 2021
- Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center StudyCirculation: Arrhythmia and Electrophysiology, 2021
- Left bundle branch pacing: A comprehensive reviewJournal of Cardiovascular Electrophysiology, 2020
- Mid-term feasibility, safety and outcomes of left bundle branch pacing–single center experienceJournal of Interventional Cardiac Electrophysiology, 2020
- Incidence, patterns, and outcomes after transvenous cardiac device lead macrodislodgment: Insights from a population-based studyHeart Rhythm, 2019
- A Novel Pacing Strategy With Low and Stable Output: Pacing the Left Bundle Branch Immediately Beyond the Conduction BlockCanadian Journal of Cardiology, 2017
- Late Displacement of a Ventricular Pacing Lead After Respiratory TherapyPacing and Clinical Electrophysiology, 2001