A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation
Authors:
- John DamilakisJDJohn Damilakis
- Antonis TzedakisATAntonis Tzedakis
- Kostas PerisinakisKPKostas Perisinakis
- Antonios E. PapadakisAPAntonios E. Papadakis
- 23 November 2010
- journal article
- Published by Wiley in Medical Physics
- Vol. 37 (12) , 6411-6420
Abstract
Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low‐dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation.Methods: The Monte Carlo N‐Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals.Results: The results consist of Monte Carlo‐generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free‐in‐air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations.Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made using the method developed in the current study.Keywords
This publication has 16 references indexed in Scilit:
- Radiation Dose to the Conceptus from Multidetector CT during Early Gestation: A Method That Allows for Variations in Maternal Body Size and Conceptus PositionRadiology, 2010
- Embryo Dose Estimates in Body CTAmerican Journal of Roentgenology, 2010
- Early First Trimester Fetal Dose Estimation Method in a Multivendor Study of 16- and 64-MDCT Scanners and Low-Dose Imaging ProtocolsAmerican Journal of Roentgenology, 2009
- Utilization of Imaging in Pregnant Patients: 10-year Review of 5270 Examinations in 3285 Patients—1997–2006Radiology, 2009
- The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulationsPhysics in Medicine & Biology, 2009
- Radiation Dose to the Fetus for Pregnant Patients Undergoing Multidetector CT Imaging: Monte Carlo Simulations Estimating Fetal Dose for a Range of Gestational Age and Patient SizeRadiology, 2008
- Early First-Trimester Fetal Radiation Dose Estimation in 16-MDCT Without and With Automated Tube Current ModulationAmerican Journal of Roentgenology, 2008
- When a pregnant woman with suspected appendicitis is referred for a CT scan, what should a radiologist do to minimize potential radiation risks?Pediatric Radiology, 2004
- Estimation of Fetal Radiation Dose from Computed Tomography Scanning in Late PregnancyInvestigative Radiology, 2000
- Overview of emergency radiological management of the pregnant patient, especially the traumatized pregnant patientEmergency Radiology, 2000