Protection of grid connected photovoltaic system during voltage sag
Authors:
- 1 October 2011
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 2030-2035
Abstract
The grid-connected power electronic inverters are highly sensitive to grid disturbances and it is important to emphasize the necessity to reduce the effects of voltage disturbances on their operation. Among the wide range of power quality disturbances, voltage sags severely affect the performance of voltage source converters (VSC) operation of distributed generation (DG) units. In this paper, small signal model of photovoltaic, DC-DC boost converter and inverter are simulated in Matlab simulink software. The photovoltaic system is connected to a 20kV distribution feeder via a transformer. It can be seen if the voltage sag is happened in the system, the inverter switch current will be increased significantly. In order to protect the power electronic converters' switches during a voltage sag and increase the voltage sag ride through capability, use of fault current limiter (FCL), is proposed. It is shown that if the voltage sag happened with duration of half to thirty cycles, FCL limits the current of power electronic switches. So, the photovoltaic system although is kept connecting with grid during the voltage sag condition, the power electronic switches aren't harmed and have normal current during voltage sag duration.Keywords
This publication has 13 references indexed in Scilit:
- Fuzzy neural control of a hybrid fuel cell/battery distributed power generation systemIET Renewable Power Generation, 2009
- Providing Ride-Through Capability to a Doubly Fed Induction Generator Under Unbalanced Voltage DipsIEEE Transactions on Power Electronics, 2009
- Voltage dips at the terminals of wind power installationsWind Energy, 2005
- A New Algorithm for Rapid Tracking of Approximate Maximum Power Point in Photovoltaic SystemsIEEE Power Electronics Letters, 2004
- Different methods for classification of three-phase unbalanced voltage dips due to faultsElectric Power Systems Research, 2003
- Understanding Power Quality Problems1999
- Solid-state distribution current limiter and circuit breaker: application requirements and control strategiesIEEE Transactions on Power Delivery, 1993
- Assessment study of superconducting fault-current limiters operating at 77 KIEEE Transactions on Power Delivery, 1993
- Voltage sags in industrial systemsIEEE Transactions on Industry Applications, 1993
- Towards the superconducting fault current limiterIEEE Transactions on Power Delivery, 1991