Fast spin‐echo MR imaging of the abdomen: Contrast optimization and artifact reduction
Authors:
- 1 September 1994
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 4 (5) , 637-645
Abstract
The effects of various fast spin‐echo (FSE) magnetic resonance (MR) imaging parameters and artifact reduction techniques on FSE image contrast and quality were studied. The authors performed 139 abdominal MR examinations, comparing standard FSE images (echo train length [ETL] = 8, echo space [E‐space] = 17 msec, bandwidth = ±16‐kHz) with FSE images with an ETL of 16 (n = 22) or FSE images with a ±32‐kHz bandwidth and an E‐space of 11‐14 msec (n = 22). FSE artifact reduction techniques were evaluated with spectral fat saturation (n = 40) or with a new flow compensation FSE sequence (n = 55). Images of liver lesions were reviewed qualitatively and with contrast‐to‐noise ratio (C/N) measurements. Decreasing the time of echo train sampling produced superior image quality, with increased anatomic sharpness, less image artifact, and improved liver‐lesion C/N. Images obtained with an ETL of 16 showed more image blurring and a 23% decrease in relative contrast and 28% decrease in relative C/N for liver tumors. Increasing the bandwidth reduced E‐space, producing a 12% decrease in background noise. Artifact reduction with fat saturation or flow compensation produced images with less ghosting artifact and superior overall image quality, with 39% and 20% increases in liver‐tumor C/N, respectively. FSE image quality and contrast in the depiction of hepatic disease can be optimized with careful selection of imaging parameters and the use of artifact reduction techniques.Keywords
This publication has 18 references indexed in Scilit:
- Prospective comparison of T2-weighted fast spin-echo, with and without fat suppression, and conventional spin-echo pulse sequences in the upper abdomen.Radiology, 1993
- Abdominal MR imaging: comparison of T2-weighted fast and conventional spin-echo, and contrast-enhanced fast multiplanar spoiled gradient-recalled imaging.Radiology, 1993
- The pelvis: T2-weighted fast spin-echo MR imaging.Radiology, 1992
- Fast spin-echo MR imaging of the female pelvis. Part I. Use of a whole-volume coil.Radiology, 1992
- Fast spin-echo MR imaging of the brain and spine: current concepts.American Journal of Roentgenology, 1992
- Magnetization transfer of hepatic lesions: evaluation of a novel contrast technique in the abdomen.Radiology, 1992
- Liver and pancreas: improved spin-echo T1 contrast by shorter echo time and fat suppression at 1.5 T.Radiology, 1991
- Fat-saturation MR imaging of the upper abdomen.American Journal of Roentgenology, 1990
- Improving MR image quality in the presence of motion by using rephasing gradientsAmerican Journal of Roentgenology, 1987
- RARE imaging: A fast imaging method for clinical MRMagnetic Resonance in Medicine, 1986