Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarction
- 29 January 2005
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 15 (4) , 714-720
Abstract
The aim of this study was to assess global left ventricular (LV) function and regional wall motion using retrospectively ECG-gated 16-slice computed tomography (CT) in comparison with magnetic resonance imaging (MRI). Twenty-one patients (18 male, 65.5±8.6 years) with acute myocardial infarction underwent multislice spiral CT (MSCT) and MRI. From manually drawn endo- and epicardial contours, LV volumes including myocardial mass, peak filling rate (PFR), peak ejection rate (PER), time to PER (TPER) and time from end-systole to PFR (TPFR) were calculated. Regional wall motion was assessed from cine loops using a 16-segment model of the left ventricle. LV function was analyzed using the Bland–Altman method, Pearson’s correlation coefficient, multivariate analysis and post hoc t tests. Regional wall motion was evaluated with weighted kappa-statistics. Multivariate analysis revealed significant differences for global LV function as determined by MSCT and MRI. Post hoc t-tests showed significant differences for end-diastolic volume (EDV), PFR and TPER (Pκ=0.791. Sixteen-slice spiral CT allows for reliable assessment of LV volumes, but is not yet suited for the evaluation of all functional parameters. Assessment of regional wall motion at rest is feasible.Keywords
This publication has 30 references indexed in Scilit:
- Time-effectiveness, Observer-dependence, and Accuracy of Measurements of Left Ventricular Ejection Fraction Using 4-channel MDCTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar ReconstructionCirculation, 2003
- Quantifizierung der Herzfunktion in der Mehrschicht Spiral CT mit retrospektivem EKG-Gating: Vergleich zur KernspintomographieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- New Technical Developments in Multislice CT, Part 2: Sub-Millimeter 16-Slice Scanning and Increased Gantry Rotation Speed for Cardiac ImagingRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2002
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002
- MRI-derived ventricular volume curves for the assessment of left ventricular functionMagnetic Resonance Imaging, 1994
- Mode of death in idiopathic dilated cardiomyopathy: A multivariate analysis of prognostic determinantsAmerican Heart Journal, 1988
- Comparison of an Ionic with a Nonionic Contrast Agent for Cardiac AngiographyInvestigative Radiology, 1985
- Hemodynamic and electrocardiographic effects in man of a new nonionic contrast agent (iohexol): Advantages over standard ionic agentsThe American Journal of Cardiology, 1983
- Two-dimensional echocardiography and infarct size: relationship of regional wall motion and thickening to the extent of myocardial infarction in the dog.Circulation, 1981