Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging
Authors:
Open Access
- 1 August 2015
- journal article
- Published by Jaypee Brothers Medical Publishing in Indian Journal of Critical Care Medicine
- Vol. 19 (8) , 466-470
Abstract
Analysis to correlate the measurements of optic nerve sheath diameter (ONSD) obtained by using ultrasound to magnetic resonance imaging (MRI) techniques in order to establish the accuracy of ocular sonography as a noninvasive modality for detecting raised intracranial pressure (ICP). A prospective, observational study was performed in 100 cases of adult meningoencephalitis patients admitted to Intensive Care Unit in whom MRI was performed for neurodiagnosis. ONSD was measured in such patients, 3 mm behind the globe in each eye. A mean binocular ONSD >4.6 mm in female and 4.8 mm in male was taken as cut-off values for diagnosing raised ICP. This was compared with ONSD measured on T2-weighted MRI image measured 3 mm behind the globe. The reading obtained from both the methods were compared with Bland-Altman analysis for correlation and the findings were tabulated. The mean ONSD values measured with ultrasonography (USG) and MRI for female were 5.48 ± 0.43 mm and 5.68 ± 0.44 mm and for male were 5.40 ± 0.37 mm and 5.56 ± 0.38 mm, respectively. The mean age of the female and male was 53.90 ± 17.84 and 56.06 ± 15.67 years, respectively. On comparing ultrasound with MRI-derived ONSD values, we found acceptable agreement between both methods for measurements at a depth of 3 mm (r = 0.02, P < 0.001). In our study, we have found a good correlation between ocular USG and MRI of ONSD. The study has shown agreement with the fact that ocular sonography can be used as a noninvasive tool for detecting raised ICP with accuracy.Keywords
This publication has 28 references indexed in Scilit:
- Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational studyIndian Journal of Critical Care Medicine, 2014
- Association Between Optic Nerve Sheath Diameter and Mortality in Patients with Severe Traumatic Brain InjuryNeurocritical Care, 2014
- Optic Nerve Sheath Diameter Used as Ultrasonographic Assessment of the Incidence of Raised Intracranial Pressure in PreeclampsiaAnesthesiology, 2012
- Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysisIntensive Care Medicine, 2011
- Optic Nerve Ultrasound for Detection of Intracranial Hypertension in Intracranial Hemorrhage PatientsJournal of Neurosurgical Anesthesiology, 2009
- Cerebrospinal fluid dynamics between the intracranial and the subarachnoid space of the optic nerve. Is it always bidirectional?Brain, 2006
- Idiopathic intracranial hypertension: the validity of cross-sectional neuroimaging signsNeuroradiology, 2006
- Magnetic resonance imaging in pseudotumor cerebriOphthalmology, 1998
- Echographic measurement of the optic nerve in patients with intracranial hypertensionmin - Minimally Invasive Neurosurgery, 1987
- PATHOGENESIS OF OEDEMA OF THE OPTIC DISC (PAPILLOEDEMA): A PRELIMINARY REPORTBritish Journal of Ophthalmology, 1964