Femoral Neck Fracture Following Hardware Removal
Authors:
- James A. ShaerJSJames A. Shaer
- Barbara M. HilemanBHBarbara M. Hileman
- Jill E. NewcomerJNJill E. Newcomer
- Marina C. HanesMHMarina C. Hanes
- 1 January 2012
- journal article
- case report
- Published by SLACK, Inc. in Orthopedics
- Vol. 35 (1) , e83-7
Abstract
It is uncommon for femoral neck fractures to occur after proximal femoral hardware removal because age, osteoporosis, and technical error are often noted as the causes for this type of fracture. However, excessive alcohol consumption and failure to comply with protected weight bearing for 6 weeks increases the risk of femoral neck fractures. This article describes a case of a 57-year-old man with a high-energy ipsilateral inter-trochanteric hip fracture, comminuted distal third femoral shaft fracture, and displaced lateral tibial plateau fracture. Cephalomedullary fixation was used to fix the ipsilateral femur fractures after medical stabilization and evaluation of the patient. The patient healed clinically and radiographically at 6 months. Despite conservative treatment for painful proximal hardware, elective hip screw removal was performed 22.5 months after injury. Seven weeks later, he sustained a nontraumatic femoral neck fracture. In this case, it is unlikely that the femoral neck fracture occurred as a result of hardware removal. We assumed that, in addition to the patient’s alcohol abuse and tobacco use, stress fractures may have attributed to the femoral neck fracture. We recommend using a shorter hip screw to minimize hardware prominence or possibly off-label use of an injectable bone filler, such as calcium phosphate cement.Keywords
This publication has 19 references indexed in Scilit:
- Femoral Neck Fracture After Arthroscopic Management of Femoroacetabular ImpingementJournal of Bone and Joint Surgery, 2011
- Viscoelastic properties of injectable bone cements for orthopaedic applications: State‐of‐the‐art reviewJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2011
- Comparison of Bipolar Hemiarthroplasty with Total Hip Arthroplasty for Displaced Femoral Neck FracturesJournal of Bone and Joint Surgery, 2011
- Calcium Phosphates: What Is the Evidence?Journal of Orthopaedic Trauma, 2010
- Association Between Alcohol Consumption and Both Osteoporotic Fracture and Bone DensityThe American Journal of Medicine, 2008
- Calcium Phosphate Cement Augmentation of the Femoral Neck Defect Created After Dynamic Hip Screw RemovalJournal of Orthopaedic Trauma, 2007
- Complications following the treatment of trochanteric fractures with the gamma nailArchives of orthopaedic and trauma surgery, 2004
- Skeletal Response to AlcoholAlcohol, Clinical and Experimental Research, 2000
- Bone and the ‘Comforts of Life’Annals of Medicine, 1993
- Fracture of the Femoral Neck after Internal Fixation1988