Abstract
Distortion-product otoacoustic emissions (DPOAEs) were used to describe suppression growth in normal-hearing humans. Data were collected at eight f2 frequencies ranging from 0.5 to 8 kHz for L2 levels ranging from 10 to 60 dB sensation level. For each f2 and L2 combination, suppression was measured for nine or eleven suppressor frequencies (f3) whose levels varied from −20 to 85 dB sound pressure level (SPL). Suppression grew nearly linearly when f3 ≈ f2, grew more rapidly for f3 < f2, and grew more slowly for f3 > f2. These results are consistent with physiological and mechanical data from lower animals, as well as previous DPOAE data from humans, although no previous DPOAE study has described suppression growth for as wide a range of frequencies and levels. These trends were evident for all f2 and L2 combinations; however, some exceptions were noted. Specifically, suppression growth rate was less steep as a function of f3 for f2 frequencies ≤1 kHz. Thus, despite the qualitative similarities across frequency, there were quantitative differences related to f2, suggesting that there may be subtle differences in suppression for frequencies above 1 kHz compared to frequencies below 1 kHz.

This publication has 44 references indexed in Scilit: