Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography
Authors:
- 8 May 2009
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 19 (10) , 2373-2382
Abstract
The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s. For group 2 injection parameters were individually adjusted to patient weight, the duration of CT data acquisition, and attenuation parameters following a test bolus. In the control group (group 3) the volume of CM was adjusted to the duration of CT data acquisition and injected at 5 mL/s. Attenuation was measured in the proximal, middle, and distal right coronary artery (RCA), in the proximal and middle left anterior descending artery (LAD), and in cranial and caudal sections of both ventricles. Patient parameters, scan delay, and scan duration did not differ significantly between the groups. Mean CM volume was 82.5 mL (flow rate 5.1 mL/s) in group 2 and 73.5 mL in group 3. Attenuation in both RCA and LAD was significantly higher for group 2 vs. group 3 (RCA: 414.9 + or - 49.9)-396.1(+ or - 52.1) HU vs. 366.0(+ or - 64.3)-341.6(+ or - 72.5) HU; LAD: 398.9(+ or - 48.6)-364.6(+ or - 44.6) HU vs. 356.3(+ or - 69.5)-323.0(+ or - 67.2) HU). For group 1 vs. group 2 only attenuation in the distal RCA differed significantly: 396.1(+ or - 52.1) vs. 370.7(+ or - 70.5) HU. Individually tailored CM injection protocols yield higher attenuation, especially in the distal segments of the coronary vessels, compared with injection protocols using fixed injection parameters.Keywords
This publication has 44 references indexed in Scilit:
- Right Heart: Split-Bolus Injection of Diluted Contrast Medium for Visualization at Coronary CT AngiographyRadiology, 2008
- Comparison of Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography in Women Versus Men With Angina PectorisThe American Journal of Cardiology, 2007
- Diagnostic Accuracy of Dual-Source Computed Tomography in the Diagnosis of Coronary Artery DiseaseInvestigative Radiology, 2007
- CT Coronary Angiography Using 16 and 64 Simultaneous Detector Rows: Intraindividual ComparisonRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2007
- Contrast-enhanced coronary artery visualization by dual-source computed tomography—Initial experienceEuropean Journal of Radiology, 2006
- Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient WeightRadiology, 2004
- Optimal Contrast Application for Cardiac 4-Detector-Row Computed TomographyInvestigative Radiology, 2003
- Peak Contrast Enhancement in CT and MR Angiography: When Does It Occur and Why? Pharmacokinetic Study in a Porcine ModelRadiology, 2003
- Composition of coronary atherosclerotic plaques in patients with acute myocardial infarction and stable angina pectoris determined by contrast-enhanced multislice computed tomographyThe American Journal of Cardiology, 2003
- Accuracy of Predicting and Controlling Time-Dependent Aortic Enhancement from a Test Bolus InjectionJournal of Computer Assisted Tomography, 2001