Heart transplantation of patients with ventricular assist devices: impact of normothermic ex-vivo preservation using organ care system compared with cold storage
Preprint
- 15 October 2020
- preprint
- Published by Springer Nature in Research Square
Abstract
Background: Organ Care System (OCS) minimizes the cold ischemic time and allows for optimization of logistics and meticulous recipient preparation. Impact of normothermic ex-vivo preservation using OCS compared with cold storage (CS) for prolonged heart preservation especially beneficial for high-risk recipients bridged to transplantation with Mechanical Circulatory Support (MCS).Methods: Between 2012 and 2018, we performed a retrospective single-center review of prospectively collected data. All patients who underwent heart transplantation with MCS using the OCS Heart (n=25) versus standard cold storage (n=10) were included in this study. Results: During this period, 353 patients were implanted with left ventricular assisted device (LVAD) and 35 (10 %) were bridged to heart transplantation. There was no significant difference in donor and recipient characteristics and risk factors. The Index for Mortality Prediction after Cardiac Transplantation (IMPACT) score was a trend towards higher estimated risk of death at 1y in the OCS group (14.2 vs. 10.8% p= 0.083). Mean total ischemic time during preservation was statistically significantly longer in CS vs OCS group (210 (23) Vs 74.6 (13) min p=0.001). Median ex vivo normothermic heart perfusion time in OCS was 348.4(132; 955) min. There was significant difference in total out of body time between OCS group 423(67) Vs CS group 210(23) min p=0.002). All patients were alive on the 30th days post implant in CS groups and 96% in OCS group (p=0.5).Conclusion: Normothermic ex-vivo preservation of the allograft during transportation with the organ care system might be beneficial for long-time out of body organ preservation in comparison of cold storage especially for recipients on mechanical circulatory support.Keywords
All Related Versions
This publication has 9 references indexed in Scilit:
- Comparison of Custodiol vs warm blood cardioplegia and conditioning of donor hearts during transportation with the organ care systemJournal of Cardiac Surgery, 2019
- Sixteen‐Hour Ex Vivo Donor Heart Perfusion During Long‐Distance Transportation for Heart TransplantationArtificial Organs, 2018
- Initial 3-year Outcomes with Left Ventricular Assist Devices in a Country with a Nascent Heart Transplantation ProgramESC Heart Failure, 2015
- Cardiac Transplantation After Bridged Therapy with Continuous Flow Left Ventricular Assist DevicesHeart, Lung and Circulation, 2014
- Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patientsThe Journal of Heart and Lung Transplantation, 2013
- The Registry of the International Society for Heart and Lung Transplantation: 29th Official Adult Heart Transplant Report—2012The Journal of Heart and Lung Transplantation, 2012
- Factors Associated With Primary Graft Failure After Heart TransplantationTransplantation, 2010
- Posttransplant survival is not diminished in heart transplant recipients bridged with implantable left ventricular assist devicesThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Registry of the International Society for Heart and Lung Transplantation: Twenty-sixth Official Adult Heart Transplant Report—2009The Journal of Heart and Lung Transplantation, 2009