Reduced Tissue-Interface Pressure and Increased Comfort on a Newly Developed Soft-Layered Long Spineboard
Authors:
- Baukje HemmesBHBaukje Hemmes
- Martijn PoezeMPMartijn Poeze
- Peter R. G. BrinkPBPeter R. G. Brink
- 1 March 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 68 (3) , 593-598
Abstract
: Immobilization of the spine in patients with trauma at risk of spinal damage is performed using a rigid long spineboard or vacuum mattress both during prehospital and in-hospital care. However, disadvantages of these immobilization devices in terms of discomfort and tissue-interface pressures have guided the development of a new soft-layered long spineboard. We compared tissue-interface pressure and degree of discomfort during immobilization on a rigid spineboard, a vacuum mattress, and a newly developed soft-layered long spineboard.: In this randomized crossover trial, 30 volunteers were immobilized sequentially on all three devices for 15 minutes per device. Tissue-interface pressures were measured using an Xsensor pressure mapping device, including the peak pressure and the Peak Pressure Index (PPI). Discomfort was rated on a Visual Analog Scale after 1 minute and after 15 minutes of immobilization.: Tissue-interface pressures were significantly higher on the standard long spineboard and the vacuum mattress than on the soft-layered long spineboard. PPI for the sacrum was close to peak pressure on both the spineboard and the vacuum mattress. PPI for the sacrum on the soft-layered long spineboard was significantly lower, with an average PPI close to normal diastolic blood pressures. The participants reported significantly less discomfort on the soft-layered long spineboard compared with the rigid long spineboard, both after 1 minute and 15 minutes (p < 0.0001).: This study revealed a relevant reduction in tissue-interface pressures and discomfort when using a soft-layered long spineboard compared with using a standard rigid long spineboard or a vacuum mattress. Emergency care providers should consider the use of the soft-layered long spineboard to reduce the discomfort and potential tissue damage caused by immobilization and transport on a rigid long spineboard or vacuum mattress.Keywords
This publication has 34 references indexed in Scilit:
- A repeat audit of spinal board usage in the emergency departmentInjury, 2008
- Reduced time on the spinal board—effects of guidelines and education for emergency department staffInjury, 2006
- Managing spinal immobilisation devices in the emergency departmentAustralasian Emergency Nursing Journal, 2005
- Is there a Reason for Spine Board Immobilization in the Emergency Department for Patients with a Potential Spinal Injury?European Journal of Trauma, 2005
- P ATIENT D ISCOMFORT D UE TO I NDISCRIMINANT U SE OF S PINAL I MMOBILIZATIONPrehospital Emergency Care, 2004
- Current spinal board usage in emergency departments across the UK.Injury, 2003
- The use of the spinal board after the pre-hospital phase of trauma managementEmergency Medicine Journal, 2001
- Duration of patient immobilization in the EDThe American Journal of Emergency Medicine, 2000
- Use of the spinal board within the accident and emergency department.Emergency Medicine Journal, 1998
- Pain and Tissue-Interface Pressures During Spine-Board ImmobilizationAnnals of Emergency Medicine, 1995