Development of A Textile Capacitive Proximity Sensor and Gait Monitoring System for Smart Healthcare
- 12 March 2018
- journal article
- research article
- Published by Springer Nature in Journal of Medical Systems
- Vol. 42 (4) , 76-76:12
Abstract
Gait is not only one of the most important functions and activities in daily life but is also a parameter to monitor one‘s health status. We propose a single channel capacitive proximity pressure sensor (TCPS) and gait monitoring system for smart healthcare. Insole-type TCPS (270 mm in length) was designed consisting of three layers including two shield layers and a sensor layer. Analyzing the step count and stride time are the basic indicators in gait analysis, thus they were selected as evaluation indicators. A total of 12 subjects participated in the experiment to evaluate the resolution of our TCPS. To evaluate the accuracy of TCPS, step count and its error rates were simultaneously detected by naked eye, ZIKTO Walk (ZIKTO Co., Korea), and HJ-203-K pedometer (Omron Co., Japan) as reference. Results showed that the error rate of 1.77% in TCPS was lower than those of other devices and correlation coefficient was 0.958 (p-value = 0.000). ZIKTO Walk and pedometer do not provide information on stride time, therefore it was detected by F-scan (Tekscan, USA) to evaluate the performance of TCPS. As a result, error rate of stride time measured by TCPS was found to be 1% and the correlation coefficient was 0.685 (p-value = 0.000). According to these results, our proposed system may be helpful in development of gait monitoring and measurement system as smart healthcare.Keywords
Funding Information
- National Research Foundation of Korea (2015M3A9D7067388)
- Ministry of Science, ICT and Future Planning (IITP-2016-H8601-16-1009)
This publication has 31 references indexed in Scilit:
- A comparison of conductive textile-based and silver/silver chloride gel electrodes in exercise electrocardiogram recordingsJournal of Electrocardiology, 2011
- Development of a wearable sensor system for quantitative gait analysisMeasurement, 2009
- Gait analysis using gravitational acceleration measured by wearable sensorsJournal of Biomechanics, 2009
- Bilateral coordination of walking and freezing of gait in Parkinson’s diseaseEuropean Journal of Neuroscience, 2008
- Wearable electromyography measurement system using cable-free network system on conductive fabricArtificial Intelligence in Medicine, 2008
- A new measure for quantifying the bilateral coordination of human gait: effects of aging and Parkinson’s diseaseExperimental Brain Research, 2007
- Footprint analysis of gait using a pressure sensor systemJournal of Electromyography and Kinesiology, 2004
- Evaluation of new technologies in health-care systems: what’s the context?Health Informatics Journal, 2000
- Can telemedicine be used to improve communication between primary and secondary care?BMJ, 1996
- Telemedicine: a cautious welcomeBMJ, 1996