Comparison of utility of deep learning reconstruction on 3D MRCPs obtained with three different k-space data acquisitions in patients with IPMN
Authors:
- 10 June 2022
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 32 (10) , 6658-6667
Abstract
Objective To compare the utility of deep learning reconstruction (DLR) for improving acquisition time, image quality, and intraductal papillary mucinous neoplasm (IPMN) evaluation for 3D MRCP obtained with parallel imaging (PI), multiple k-space data acquisition for each repetition time (TR) technique (Fast 3D mode multiple: Fast 3Dm) and compressed sensing (CS) with PI. Materials and methods A total of 32 IPMN patients who had undergone 3D MRCPs obtained with PI, Fast 3Dm, and CS with PI and reconstructed with and without DLR were retrospectively included in this study. Acquisition time, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) obtained with all protocols were compared using Tukey’s HSD test. Results of endoscopic ultrasound, ERCP, surgery, or pathological examination were determined as standard reference, and distribution classifications were compared among all 3D MRCP protocols by McNemar’s test. Results Acquisition times of Fast 3Dm and CS with PI with and without DLR were significantly shorter than those of PI with and without DLR (p < 0.05). Each MRCP sequence with DLR showed significantly higher SNRs and CNRs than those without DLR (p < 0.05). IPMN distribution accuracy of PI with and without DLR and Fast 3Dm with DLR was significantly higher than that of Fast 3Dm without DLR and CS with PI without DLR (p < 0.05). Conclusion DLR is useful for improving image quality and IPMN evaluation capability on 3D MRCP obtained with PI, Fast 3Dm, or CS with PI. Moreover, Fast 3Dm and CS with PI may play as substitution to PI for MRCP in patients with IPMN. Key Points • Mean examination times of multiple k-space data acquisitions for each TR and compressed sensing with parallel imaging were significantly shorter than that of parallel imaging (p < 0.0001). • When comparing image quality of 3D MRCPs with and without deep learning reconstruction, deep learning reconstruction significantly improved signal-to-noise ratio and contrast-to-noise ratio (p < 0.05). • IPMN distribution accuracies of parallel imaging with and without deep learning reconstruction (with vs. without: 88.0% vs. 88.0%) and multiple k-space data acquisitions for each TR with deep learning reconstruction (86.0%) were significantly higher than those of others (p < 0.05).Keywords
Funding Information
- Canon Medical Systems Corporation
This publication has 28 references indexed in Scilit:
- Usefulness of 3D hybrid profile order technique with 3T magnetic resonance cholangiography: Comparison of image quality and acquisition timeJournal of Magnetic Resonance Imaging, 2016
- A Revised Classification System and Recommendations From the Baltimore Consensus Meeting for Neoplastic Precursor Lesions in the PancreasAmerican Journal of Surgical Pathology, 2015
- American Gastroenterological Association Institute Guideline on the Diagnosis and Management of Asymptomatic Neoplastic Pancreatic CystsGastroenterology, 2015
- Current roles of endoscopy in the management of intraductal papillary mucinous neoplasm of the pancreasDigestive Endoscopy, 2015
- Optimized three‐dimensional fast‐spin‐echo MRIJournal of Magnetic Resonance Imaging, 2014
- Parallel MR imagingJournal of Magnetic Resonance Imaging, 2012
- Measures of Interrater AgreementJournal of Thoracic Oncology, 2011
- MDCT of Intraductal Papillary Mucinous Neoplasm of the Pancreas: Evaluation of Features Predictive of Invasive CarcinomaAmerican Journal of Roentgenology, 2006
- Cystic pancreatic neoplasmsGastrointestinal Endoscopy Clinics of North America, 2002
- Reproducibility of histomorphologic diagnoses with special reference to the kappa statisticAPMIS, 1989