Racial Disparities in Occult Hypoxemia and Clinically Based Mitigation Strategies to Apply in Advance of Technological Advancements
Authors:
- Christopher F. ChesleyCCChristopher F. Chesley
- Meghan B. Lane-FallMLMeghan B. Lane-Fall
- Michael O HarhayMHMichael O Harhay
- 3 June 2022
- journal article
- research article
- Published by SAGE Publications in Respiratory Care
- Vol. 67 (12) , 1499-1507
Abstract
BACKGROUND: Pulse oximetry is the mainstay of patient oxygen monitoring. Measurement error from pulse oximetry is more common for those with darker skin pigmentation, yet this topic remains understudied, and evidence-based clinical mitigation strategies do not currently exist. Our objectives were to measure the rate of occult hypoxemia, defined as arterial oxygen saturation (S aO 2 ) < 88% when pulse oximeter oxygen saturation was between 92–96%, in a racially diverse critically ill population; to analyze degree, direction, and consistency of measurement error; and to develop a mitigation strategy that minimizes occult hypoxemia in advance of technological advancements. METHODS: We performed a multi-center retrospective cohort study of critically ill subjects. RESULTS: Among 105,467 paired observations from 7,693 subjects, we found occult hypoxemia was more common among minority subjects. The frequency of occult hypoxemia was 7.9% versus 2.9% between Black and white subjects, respectively, ( P < .001). Pulse oximeter measurement errors were inconsistent throughout a patient encounter, with 67% of encounters having a range of intra-subject measurement errors > 4 percentage points. In 75% of encounters, the intra-subject errors were bidirectional. S aO 2 < 88% was less common at higher pulse oximeter oxygenation ranges (4.1% and 1.8% of observations among Black and white subjects at a pulse oximeter threshold of 94–98%). Although occult hypoxemia was further reduced at oxygenation saturation range 95–100%, the frequency of hyperoxemia (partial pressure of arterial oxygen > 110 mm Hg) became more common, occurring in 42.3% of Black and 46.0% of white observations. CONCLUSIONS: Measurement error in pulse oximetry is common for all racial groups, but occult hypoxemia occurred most commonly in Black subjects. The highly variable magnitude and direction of measurement error preclude an individualized mitigation approach. In advance of technological advancements, we recommend targeting a pulse oximetry saturation goal of 94–98% for all patients.Keywords
This publication has 23 references indexed in Scilit:
- Racial Bias in Pulse Oximetry MeasurementNew England Journal of Medicine, 2020
- Liberal or Conservative Oxygen Therapy for Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2020
- Conservative Oxygen Therapy during Mechanical Ventilation in the ICUNew England Journal of Medicine, 2020
- Four Types of Pulse Oximeters Accurately Detect Hypoxia during Low Perfusion and MotionAnesthesiology, 2018
- BTS guideline for oxygen use in adults in healthcare and emergency settingsThorax, 2017
- The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with HypoxemiaThe Journal of Pediatrics, 2017
- Can We Optimize Long-Term Outcomes in Acute Respiratory Distress Syndrome by Targeting Normoxemia?Annals of the American Thoracic Society, 2014
- Dark Skin Decreases the Accuracy of Pulse Oximeters at Low Oxygen Saturation: The Effects of Oximeter Probe Type and GenderAnesthesia & Analgesia, 2007
- Maximizing the Laboratory Setting for Testing Devices and Understanding Statistical Output in Pulse OximetryAnesthesia & Analgesia, 2007
- Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patientsResuscitation, 2007