Non-invasive myocardial tissue deformation and discoordination indices predict cardiac allograft vasculopathy in pediatric heart transplantation patients
Authors:
- 23 May 2024
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (7) , 1565-1574
Abstract
There is an urgent need for non-invasive imaging-based biomarkers suitable for diagnostic surveillance of cardiac allograft vasculopathy (CAV) in pediatric heart transplant (PHT) patients. The purpose of this study was to comprehensively investigate left ventricular (LV) myocardial deformation in conjunction with electromechanical discoordination in PHT. PHT patients with and without CAV were evaluated for echocardiography derived global longitudinal strain (GLS) and electromechanical discoordination indices including systolic stretch fraction (SSF) and diastolic relaxation fraction (DRF). SSF was increased in CAV(+) patients at the time of CAV diagnosis (median CAV(+) 5.0 vs. median CAV(-) 0.0, P = 0.008) and in the echocardiogram preceding the CAV diagnosis (median CAV(+) 29.0 vs. median CAV(-) 0.0, P < 0.001). DRF was also increased in the echocardiogram that preceded CAV diagnosis in CAV(+) patients (0.31 ± 0.08 vs. 0.25 ± 0.05, P = 0.008). The final model using indices 6–12 months prior to CAV diagnosis included GLS, SSF, and DRF providing AUC of 0.94 with sensitivity 98.5%, specificity 80.0%, positive predictive value 85.0%, and negative predictive value 94.1%. Systolic and diastolic electro-mechanical discoordination indices are significantly worse in PHT patients experiencing CAV. Non-invasive imaging guided surveillance using echocardiographic myocardial deformation indices can be improved by adding SSF and DRF to standard GLS measurements.Keywords
This publication has 34 references indexed in Scilit:
- Echocardiographic Detection of Increased Ventricular Diastolic Stiffness in Pediatric Heart Transplant Recipients: A Pilot StudyJournal of the American Society of Echocardiography, 2018
- Diminished Global Longitudinal Strain Predicts Late Allograft Failure in Pediatric Heart Transplant RecipientsJACC: Cardiovascular Imaging, 2017
- Worsening in Longitudinal Strain and Strain Rate Anticipates Development of Pediatric Transplant Coronary Artery Vasculopathy as Soon as One Year Following TransplantPediatric Cardiology, 2017
- Geometry as a Confounder When Assessing Ventricular Systolic FunctionJACC, 2017
- Alteration of Cardiac Deformation in Acute Rejection in Pediatric Heart Transplant RecipientsPediatric Cardiology, 2017
- Longitudinal Strain and Strain Rate Abnormalities Precede Invasive Diagnosis of Transplant Coronary Artery Vasculopathy in Pediatric Cardiac Transplant PatientsPediatric Cardiology, 2016
- Improved Detection of Cardiac Allograft VasculopathyJACC, 2015
- Usefulness of real-time three-dimensional echocardiography to quantify global left ventricular function and mechanical dyssynchrony after heart transplantationActa Cardiologica, 2011
- Recoordination Rather than Resynchronization Predicts Reverse Remodeling after Cardiac Resynchronization TherapyJournal of the American Society of Echocardiography, 2010
- Angiographic assessment of cardiac allograft vasculopathy: results of a Consensus Conference of the Task Force for Thoracic Organ Transplantation of the German Cardiac SocietyTransplant International, 2010