The Effect of Scleral Lens Reservoir Solution on Post-lens Fluid Turbidity and Settling in Patients With Keratoconus
- 16 October 2025
- journal article
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 51 (12) , 529-535
Abstract
Objectives: To evaluate the impact of using a high-viscosity hyaluronate solution in the fluid reservoir (FR) on post-lens fluid turbidity and the settling of scleral lenses (SLs). Methods: Forty-four eyes of 22 keratoconus patients were fitted SLs. SLs applied to the right eye were filled with preservative-free sodium hyaluronate solution, whereas those applied to the left eye were filled with preservative-free saline. After SL fitting, high- and low-contrast visual acuities (VAs) were measured at 0, 4, and 8 hr. The optical density of the post-lens fluid was calculated using Scheimpflug tomography and graded from anterior-segment optical coherence (AS-OCT) images. Central corneal clearance and lens settling were measured with AS-OCT. Results: High-contrast VA showed no significant change over time in either group. Low-contrast VA remained stable during 8 hr of SL wear in the right eyes, but low-contrast VA decreased at 4th and 8th hours in the left eyes. AS-OCT-based turbidity grading and the optical density increased over time, with no difference between the two solutions. The rate and amount of settling did not differ between the groups. Conclusions: High-viscosity sodium hyaluronate may sustain improved low-contrast vision in keratoconus patients compared with saline, without adversely affecting post-lens fluid turbidity or lens settling.Keywords
This publication has 33 references indexed in Scilit:
- Factors associated with patient-reported midday fogging in established scleral lens wearersContact Lens and Anterior Eye, 2020
- Scleral lens wear: Measuring inflammation in the fluid reservoirContact Lens and Anterior Eye, 2020
- Tear dynamics under scleral lensesContact Lens and Anterior Eye, 2019
- Determination of central corneal clearance in scleral lenses with an optical biometer and agreement with subjective evaluationContact Lens and Anterior Eye, 2019
- A measure of tear inflow in habitual scleral lens wearers with and without midday foggingContact Lens and Anterior Eye, 2019
- Scleral lens fitting and assessment strategiesContact Lens and Anterior Eye, 2019
- Scleral Lenses Reduce the Need for Corneal Transplants in Severe KeratoconusAmerican Journal of Ophthalmology, 2018
- Variation of clearance considering viscosity of the solution used in the reservoir and following scleral lens wear over timeContact Lens and Anterior Eye, 2017
- Change in vault during scleral lens trials assessed with anterior segment optical coherence tomographyContact Lens and Anterior Eye, 2017
- Complications and fitting challenges associated with scleral contact lenses: A reviewContact Lens and Anterior Eye, 2016