Adenosine-Modified Electrodes for the Determination of Glucose Without Using an Immobilized Redox Mediator
Authors:
- 1 August 1997
- journal article
- research article
- Published by Taylor & Francis in Analytical Letters
- Vol. 30 (11) , 1981-1992
Abstract
Adenosine-modified glassy carbon electrodes were prepared for the determination of glucose without using an immobilized redox mediator. Glucose oxidase (GOD) was immobilized with Nafion film onto an adenosine-modified electrode, which could electrochemically oxidize the immobilized GOD by differential pulse voltammetry at a peak potential of -470 mV vs. SCE. The peak can be used in the analysis of the substrate, although from the response of the GOD electrode it is not clear whether the redox centers from the GOD are dissociated completely or partially. The increase of the peak current with the concentration of glucose shows that the adenosine-modified electrode can be used for the determination of glucose. The enzymatic activity of GOD immobilized on the adenosine-modified electrode was greatly influenced by the length of electrode surface oxidation. The apparent Michaelis constant, K m' and the current maximum, I max, obtained from Lineweaver-Burk plot of the calibration curve were 33 mM and 1.9 mA respectively (r = 0.998, n = 6).Keywords
This publication has 24 references indexed in Scilit:
- Electroanalytical Detection of Glucose Using a Cyanometalate-Modified Electrode: Requirements for the Oxidation of Buried Redox Sites in Glucose OxidaseAnalytical Chemistry, 1996
- The 3D structure of glucose oxidase from Aspergillus niger. Implications for the use of GOD as a biosensor enzymeBiosensors and Bioelectronics, 1993
- Electron transfer between an electron mediator-adsorbed glucose oxidase and an electrodeJournal of Electroanalytical Chemistry, 1992
- Amperometric glucose biosensors based on redox polymer-mediated electron transferAnalytical Chemistry, 1991
- Electrical wiring of redox enzymesAccounts of Chemical Research, 1990
- Direct electrical communication between chemically modified enzymes and metal electrodes. I. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzymeThe Journal of Physical Chemistry, 1987
- Ferrocene-mediated enzyme electrode for amperometric determination of glucoseAnalytical Chemistry, 1984
- The Enzyme ElectrodeNature, 1967
- A glycoprotein structure for glucose oxidase from Aspergillus nigerArchives of Biochemistry and Biophysics, 1965
- The Oxidation of Glucose and Related Compounds by Glucose Oxidase from Aspergillus niger*Biochemistry, 1964