Catheter ablation of the parahisian accessory pathways from the aortic cusps—Experience of 20 cases—Improving the mapping strategy for better results
- 16 April 2020
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 31 (6) , 1413-1419
Abstract
Introduction: Catheter ablation of the parahisian accessory pathways (PHAP) has been established as the definitive therapy for this type of arrhythmia. However, the PHAP proximity to the normal atrioventricular conduction system makes the procedure technically challenging.Here, we have reported a case series of 20 patients with PHAP who underwent aortic access ablation to evaluate the safety and efficacy of this approach in the PHAP ablation.Methods and Results: The ablation through the aortic cusps was the successful approach in 13 of 20 (65%) of the cases. In 11 patients, the aortic approach was the initial strategy for ablation, and the accessory pathway was eliminated in seven (63.6%) of them. The aortic approach followed a failed right‐sided attempt in nine patients. In six (66.7%) patients, the ablation was successful with the aortic approach.The only independent predictor for the successful ablation with each approach was the earliest ventricular activation before delta wave (predelta time) and a right‐sided earliest ventricular activation of more than 23 ms had high sensitivity and specificity for right‐sided success.Systematically using the two strategies (right and left approaches), the ablation of the PHAP was successful in 18 (90%) patients.Conclusion: The aortic approach seems to be a safe and effective strategy for the ablation of PHAP. It can be used when the right‐sided approach fails or even considered as an initial strategy when the predelta time is less than 23 ms in the right septal region. When combining the right‐ and left‐sided approaches, the success rate is high. We believe that the retrograde aortic approach remains a key tool for this challenging ablation.Keywords
This publication has 11 references indexed in Scilit:
- Different Approaches for Catheter Ablation of Para-Hisian Accessory PathwaysCirculation: Arrhythmia and Electrophysiology, 2017
- Cryotherapy ablation of parahisian accessory pathways in childrenHeart Rhythm, 2015
- Radiofrequency catheter ablation at the non-coronary cusp for the treatment of para-hisian accessory pathwaysEP Europace, 2014
- Prevalence, risk, and benefits of radiofrequency catheter ablation at the aortic cusp for the treatment of mid to anteroseptal supra-ventricular tachyarrhythmiasInternational Journal of Cardiology, 2013
- Noninvasive 3D mapping system guided ablation of anteroseptal pathway below the aortic cuspHeart Rhythm, 2013
- Utility of Distinctive Local Electrogram Pattern and Aortographic Anatomical Position in Catheter Manipulation at Coronary CuspsJournal of Cardiovascular Electrophysiology, 2010
- Successful cryoablation in the noncoronary aortic cusp for a left anteroseptal accessory pathwayJournal of Interventional Cardiac Electrophysiology, 2008
- Safety and Efficacy of Cryoablation of Accessory Pathways Adjacent to the Normal Conduction SystemJournal of Cardiovascular Electrophysiology, 2003
- Successful Catheter Ablation of an Anteroseptal Accessory Pathway from the Noncoronary Sinus of ValsalvaJournal of Cardiovascular Electrophysiology, 2003
- Catheter Ablation of Accessory Atrioventricular Pathways (Wolff–Parkinson–White Syndrome) by Radiofrequency CurrentNew England Journal of Medicine, 1991