The Performance of Flash Replenishment Contrast-Enhanced Ultrasound for the Qualitative Assessment of Kidney Lesions in Patients with Chronic Kidney Disease
Authors:
- Rachel W. WalmerRWRachel W. Walmer
- Victor S. RitterVRVictor S. Ritter
- Anush SridharanASAnush Sridharan
- Sandeep K. KasojiSKSandeep K. Kasoji
- Ersan AltunEAErsan Altun
- Ellie LeeELEllie Lee
- Kristen OlingerKOKristen Olinger
- Sean WagnerSWSean Wagner
- Roshni RadhakrishnaRRRoshni Radhakrishna
- Kennita A. JohnsonKJKennita A. Johnson
- W. Kimryn RathmellWRW. Kimryn Rathmell
- Bahjat QaqishBQBahjat Qaqish
Open Access
- 12 October 2023
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (20) , 6494
Abstract
We investigated the accuracy of CEUS for characterizing cystic and solid kidney lesions in patients with chronic kidney disease (CKD). Cystic lesions are assessed using Bosniak criteria for computed tomography (CT) and magnetic resonance imaging (MRI); however, in patients with moderate to severe kidney disease, CT and MRI contrast agents may be contraindicated. Contrast-enhanced ultrasound (CEUS) is a safe alternative for characterizing these lesions, but data on its performance among CKD patients are limited. We performed flash replenishment CEUS in 60 CKD patients (73 lesions). Final analysis included 53 patients (63 lesions). Four readers, blinded to true diagnosis, interpreted each lesion. Reader evaluations were compared to true lesion classifications. Performance metrics were calculated to assess malignant and benign diagnoses. Reader agreement was evaluated using Bowker’s symmetry test. Combined reader sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for diagnosing malignant lesions were 71%, 75%, 45%, and 90%, respectively. Sensitivity (81%) and specificity (83%) were highest in CKD IV/V patients when grouped by CKD stage. Combined reader sensitivity, specificity, PPV, and NPV for diagnosing benign lesions were 70%, 86%, 91%, and 61%, respectively. Again, in CKD IV/V patients, sensitivity (81%), specificity (95%), and PPV (98%) were highest. Inter-reader diagnostic agreement varied from 72% to 90%. In CKD patients, CEUS is a potential low-risk option for screening kidney lesions. CEUS may be particularly beneficial for CKD IV/V patients, where kidney preservation techniques are highly relevant.Keywords
Funding Information
- National Center for Advancing Translational Sciences (UL1TR002489)
This publication has 32 references indexed in Scilit:
- Comparison of contrast-enhanced sonography with MRI in the diagnosis of complex cystic renal massesJournal of Clinical Ultrasound, 2014
- Contrast-enhanced ultrasonography for evaluation of cystic renal mass: in comparison to contrast-enhanced CT and conventional ultrasoundAbdominal Radiology, 2014
- Evaluation of Indeterminate Renal Masses with Contrast-enhanced US: A Diagnostic Performance StudyRadiology, 2014
- Dynamic Microbubble Contrast-enhanced US to Measure Tumor Response to Targeted Therapy: A Proposed Clinical Protocol with Results from Renal Cell Carcinoma Patients Receiving Antiangiogenic TherapyRadiology, 2011
- Renal Lesions: Characterization with Diffusion-weighted Imaging versus Contrast-enhanced MR ImagingRadiology, 2009
- Comparison of Contrast-Enhanced Sonography with Unenhanced Sonography and Contrast-Enhanced CT in the Diagnosis of Malignancy in Complex Cystic Renal MassesAmerican Journal of Roentgenology, 2008
- Assessment of cystic renal masses based on Bosniak classification: Comparison of CT and contrast-enhanced USEuropean Journal of Radiology, 2007
- How I Do It: Evaluating Renal MassesRadiology, 2005
- The Bosniak classification of renal cystic massesBJU International, 2005
- CT of cystic renal masses: analysis of diagnostic performance and interobserver variation.American Journal of Roentgenology, 1997