A reduced graphene oxide based electrochemical biosensor for tyrosine detection
Authors:
- Jingjing QiuJQJingjing Qiu
- Li LiLLLi Li
- Liqiang RenLRLiqiang Ren
- Xianwen ZhangXZXianwen Zhang
- Jharna ChaudhuriJCJharna Chaudhuri
- Shiren WangSWShiren Wang
- 3 August 2012
- journal article
- Published by IOP Publishing in Nanotechnology
- Vol. 23 (33) , 335707
Abstract
In this paper, a 'green' and safe hydrothermal method has been used to reduce graphene oxide and produce hemin modified graphene nanosheet (HGN) based electrochemical biosensors for the determination of l-tyrosine levels. The as-fabricated HGN biosensors were characterized by UV-visible absorption spectra, fluorescence spectra, Fourier transform infrared spectroscopy (FTIR) spectra and thermogravimetric analysis (TGA). The experimental results indicated that hemin was successfully immobilized on the reduced graphene oxide nanosheet (rGO) through π-π interaction. TEM images and EDX results further confirmed the attachment of hemin on the rGO nanosheet. Cyclic voltammetry tests were carried out for the bare glass carbon electrode (GCE), the rGO electrode (rGO/GCE), and the hemin-rGO electrode (HGN/GCE). The HGN/GCE based biosensor exhibits a tyrosine detection linear range from 5 × 10(-7) M to 2 × 10(-5) M with a detection limitation of 7.5 × 10(-8) M at a signal-to-noise ratio of 3. The sensitivity of this biosensor is 133 times higher than that of the bare GCE. In comparison with other works, electroactive biosensors are easily fabricated, easily controlled and cost-effective. Moreover, the hemin-rGO based biosensors demonstrate higher stability, a broader detection linear range and better detection sensitivity. Study of the oxidation scheme reveals that the rGO enhances the electron transfer between the electrode and the hemin, and the existence of hemin groups effectively electrocatalyzes the oxidation of tyrosine. This study contributes to a widespread clinical application of nanomaterial based biosensor devices with a broader detection linear range, improved stability, enhanced sensitivity and reduced costs.Keywords
This publication has 31 references indexed in Scilit:
- Separation and determination of l-tyrosine and its metabolites by capillary zone electrophoresis with a wall-jet amperometric detectionTalanta, 2006
- Voltammetric determination of tyrosine based on an l-serine polymer film electrodeColloids and Surfaces B: Biointerfaces, 2006
- Determination of nitrotyrosine and tyrosine by high-performance liquid chromatography with tandem mass spectrometry and immunohistochemical analysis in livers of mice administered acetaminophenJournal of Pharmaceutical and Biomedical Analysis, 2006
- Liquid chromatography–tandem mass spectrometry method for the simultaneous determination of δ-ALA, tyrosine and creatinine in biological fluidsClinica Chimica Acta, 2004
- Determination of amino acids in overlapped capillary electrophoresis peaks by means of partial least-squares regressionJournal of Chromatography A, 2000
- Determination of the l-DOPA/l-tyrosine ratio in human plasma by high-performance liquid chromatographyJournal of Chromatography B: Biomedical Sciences and Applications, 1997
- Indirect electrochemical determination of L-tyrosine using mushroom tyrosinase in solutionAnalytical Chemistry, 1991
- Treatment with tyrosine, a neurotransmitter precursor, reduces environmental stress in humansBrain Research Bulletin, 1989
- Effect of the Anorectic Drug, Phenylpropanolamine, on Blood Glucose in RatsPharmacology, 1978
- Neurotransmitter Precursor Amino Acids in the Treatment of Multi‐Infarct Dementia and Alzheimer's Disease†Journal of the American Geriatrics Society, 1977