The effect of temperature and initial pH on biomimetic apatite coating
- 3 April 2008
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 87B (1) , 204-212
Abstract
Bone‐like apatite coatings were prepared using a biomimetic method in a simulated body fluid (SBF). The effect of initial pH values and immersing temperatures on biomimetic apatite coating formation was studied. Three different temperatures were used in this study: 24 (room temperature), 40, and 60°C. At each temperature, SBF solutions with three different initial pHs were chosen: low, medium, and high. The total inorganic carbon (TIC) content and pH‐time profile of each coating system were recorded during the coating formation. The apatite coatings were characterized using X‐ray diffraction (XRD), field emission scanning electron microscope (FESEM), and Fourier transform infra‐red (FTIR). It has been found that SBF temperature has a great effect on the bicarbonate decomposition rate. The bicarbonate ions tend to decompose faster as the temperature increases. The decomposition of bicarbonate ions results in a pH increase in the SBF. With different initial SBF pHs, the decomposition of different amounts of bicarbonate ions is required to reach the critical pH range of apatite formation. With different amounts of bicarbonate ions in the SBF, the surface morphology of the biomimetic apatite coating formed is different. Therefore, the initial pH of the SBF solution plays a vital role in controlling the surface morphology of the biomimetic apatite coating. Also, it was found that as the SBF temperature increased, the critical pH range at which biomimetic apatite coating forms decreased. The critical pH range for the SBF prepared at 24, 40, and 60°C was 6.65–6.71, 6.55–6.65, and 6.24–6.42, respectively. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2008Keywords
This publication has 34 references indexed in Scilit:
- Porous poly(L-lactic acid)/apatite composites created by biomimetic processJournal of Biomedical Materials Research, 1999
- Quasi-biological apatite film induced by titanium in a simulated body fluidJournal of Biomedical Materials Research, 1998
- Formation and characteristics of the apatite layer on plasma-sprayed hydroxyapatite coatings in simulated body fluidBiomaterials, 1997
- Bioactivity of Na 2 O‐CaO‐SiO 2 GlassesJournal of the American Ceramic Society, 1995
- Bonelike Hydroxyapatite Induction by a Gel‐Derived Titania on a Titanium SubstrateJournal of the American Ceramic Society, 1994
- Process of formation of bone-like apatite layer on silica gelJournal of Materials Science: Materials in Medicine, 1993
- Apatite Formation Induced by Silica Gel in a Simulated Body FluidJournal of the American Ceramic Society, 1992
- Bioactivity of CaO SiO2-based glasses:in vitro evaluationJournal of Materials Science: Materials in Medicine, 1990
- Solutions able to reproduce in vivo surface‐structure changes in bioactive glass‐ceramic A‐W3Journal of Biomedical Materials Research, 1990
- Ca, P‐rich layer formed on high‐strength bioactive glass‐ceramic A‐WJournal of Biomedical Materials Research, 1990