Correlation of Biexponential Diffusion Parameters With Arterial Spin-Labeling Perfusion MRI
Authors:
- Hans-Jörg WittsackHWHans-Jörg Wittsack
- Till HeusnerTHTill Heusner
- Christian BuchbenderCBChristian Buchbender
- Michael Nguyen QuangMQMichael Nguyen Quang
- Petros MartirosianPMPetros Martirosian
- Philip BilkPBPhilip Bilk
- Patric KröpilPKPatric Kröpil
- Dirk BlondinDBDirk Blondin
- Gerald AntochGAGerald Antoch
- Rotem S. LanzmanRLRotem S. Lanzman
- 1 March 2013
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 48 (3) , 140-144
Abstract
The purpose of the present study was to explore the correlation between diffusion parameters assessed by biexponential analysis and the tissue perfusion measured by arterial spin labeling (ASL) imaging in renal allografts. Seventeen recipients of renal allograft (11 men and 6 women; mean [SD] age, 53.6 [14.1] years) were included in this study. For diffusion-weighted imaging, a paracoronal echo-planar imaging sequence was acquired with 16 b values (range, b = 0-750 s/mm²) and 6 averages at 1.5 T. For the quantitative assessment of transplanted kidney perfusion, a flow-sensitive alternating inversion recovery true fast imaging with steady precession-ASL technique was applied. No respiratory gating was used. For quantitative analysis, region of interest measurements were performed on parameter maps. The Spearman correlation coefficients were calculated to determine the association between mean serum creatinine levels, estimated glomerular filtration rate, the apparent diffusion coefficient (ADC) of pure diffusion, the ADC of pseudodiffusion, the monoexponential ADC, the fraction of pseudodiffusion, and the tissue perfusion ASL values. In the renal cortex, the fraction of pseudodiffusion was 17.4% ± 4.0%, the apparent diffusion coefficient of pure diffusion was 160.7 ± 15.0 × 10⁻⁵ mm²/s, the monoexponential ADC was 193.2 ± 16.7 × 10⁻⁵ mm²/s, and the ADC of pseudodiffusion was 1421.0 ± 237.7 × 10⁻⁵ mm²/s. Mean cortical perfusion of renal allografts, as assessed with ASL imaging, was 247.2 ± 75.0 mL/100 g/min. There was a significant correlation between ASL perfusion and the fraction of pseudodiffusion (r = 0.68; P < 0.005) but not with the other diffusion coefficients. Both ASL perfusion and the fraction of pseudodiffusion exhibited a significant correlation with serum creatinine levels (r = 0.51 and r= 0.53, respectively; P < 0.05) and estimated glomerular filtration rate (r = 0.63 and r = 0.54, respectively; P < 0.05). This is the first study that shows a significant correlation between renal allograft perfusion, as assessed with ASL perfusion measurements, and the fraction of pseudodiffusion derived from biexponential diffusion-weighted imaging measurements.Keywords
This publication has 34 references indexed in Scilit:
- Histogram Analysis of Renal Arterial Spin Labeling Perfusion Data Reveals Differences Between Volunteers and Patients With Mild Chronic Kidney DiseaseInvestigative Radiology, 2012
- Impact of Iso- and Low-Osmolar Iodinated Contrast Agents on BOLD and Diffusion MRI in Swine KidneysInvestigative Radiology, 2012
- Temporally Resolved Electrocardiogram-Triggered Diffusion-Weighted Imaging of the Human KidneyInvestigative Radiology, 2012
- Investigation of prostate cancer using diffusion-weighted intravoxel incoherent motion imagingMagnetic Resonance Imaging, 2011
- Reproducibility of renal perfusion MR imaging in native and transplanted kidneys using non‐contrast arterial spin labelingJournal of Magnetic Resonance Imaging, 2011
- Statistical evaluation of diffusion‐weighted imaging of the human kidneyMagnetic Resonance in Medicine, 2010
- Funktionelle MRT der Transplantatnieren: klinische Wertigkeit der DiffusionsbildgebungRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2009
- MR measurement of blood flow in the parotid gland without contrast medium: a functional study before and after gustatory stimulationNMR in Biomedicine, 2007
- FAIR true‐FISP perfusion imaging of the kidneysMagnetic Resonance in Medicine, 2004
- Prediction of Creatinine Clearance from Serum CreatinineNephron, 1976