Regularized emission image reconstruction using imperfect side information
Authors:
- J.A. FesslerJFJ.A. Fessler
- N.H. ClinthorneNCN.H. Clinthorne
- W.L. RogersWRW.L. Rogers
- 1 October 1992
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 39 (5) , 1464-1471
Abstract
A spatially variant penalized-likelihood method for tomographic image reconstruction based on a weighted Gibbs penalty was investigated. The penalty weights are determined from structural side information, such as the locations of anatomical boundaries in high-resolution magnetic resonance images. Such side information will be imperfect in practice, and a simple simulation demonstrated the importance of accounting for the errors in boundary locations. Methods are discussed for prescribing the penalty weights when the side information is noisy. Simulation results suggest that even imperfect side information is useful for guiding spatially variant regularizationKeywords
This publication has 13 references indexed in Scilit:
- On complete-data spaces for PET reconstruction algorithmsIEEE Transactions on Nuclear Science, 1993
- Joint maximum likelihood estimation of emission and attenuation densities in PET1991
- Image restoration using Gibbs priors: boundary modeling, treatment of blurring, and selection of hyperparameterIEEE Transactions on Pattern Analysis and Machine Intelligence, 1991
- Performance evaluation of an iterative image reconstruction algorithm for positron emission tomographyIEEE Transactions on Medical Imaging, 1991
- Bayesian image reconstruction in positron emission tomographyIEEE Transactions on Nuclear Science, 1990
- Bayesian reconstructions from emission tomography data using a modified EM algorithmIEEE Transactions on Medical Imaging, 1990
- Convergence of EM image reconstruction algorithms with Gibbs smoothingIEEE Transactions on Medical Imaging, 1990
- A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priorsIEEE Transactions on Medical Imaging, 1989
- A Bayesian Reconstruction Algorithm for Emission Tomography using a Markov Random Field Prior1989
- Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission TomographyIEEE Transactions on Medical Imaging, 1987