Using Artificial Intelligence to Improve the Accuracy of a Wrist-Worn, Noninvasive Glucose Monitor: A Pilot Study
- 17 May 2024
- journal article
- research article
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 19 (6) , 1546-1553
Abstract
Background: Self-monitoring of glucose is important to the successful management of diabetes; however, existing monitoring methods require a degree of invasive measurement which can be unpleasant for users. This study investigates the accuracy of a noninvasive glucose monitoring system that analyses spectral variations in microwave signals. Methods: An open-label, pilot design study was conducted with four cohorts (N = 5/cohort). In each session, a dial-resonating sensor (DRS) attached to the wrist automatically collected data every 60 seconds, with a novel artificial intelligence (AI) model converting signal resonance output to a glucose prediction. Plasma glucose was measured in venous blood samples every 5 minutes for Cohorts 1 to 3 and every 10 minutes for Cohort 4. Accuracy was evaluated by calculating the mean absolute relative difference (MARD) between the DRS and plasma glucose values. Results: Accurate plasma glucose predictions were obtained across all four cohorts using a random sampling procedure applied to the full four-cohort data set, with an average MARD of 10.3%. A statistical analysis demonstrates the quality of these predictions, with a surveillance error grid (SEG) plot indicating no data pairs falling into the high-risk zones. Conclusions: These findings show that MARD values approaching accuracies comparable to current commercial alternatives can be obtained from a multiparticipant pilot study with the application of AI. Microwave biosensors and AI models show promise for improving the accuracy and convenience of glucose monitoring systems for people with diabetes.Keywords
Funding Information
- Welsh Government’s SMART Cymru programme (2019/ED/054)
This publication has 24 references indexed in Scilit:
- Continuous glucose monitoring versus self-monitoring of blood glucose in the management of cystic fibrosis related diabetes: A systematic review and meta-analysisJournal of Cystic Fibrosis, 2022
- A head‐to‐head comparison between Guardian Connect and FreeStyle Libre systems and an evaluation of user acceptability of sensors in patients with type 1 diabetesDiabetes/Metabolism Research and Reviews, 2022
- Wearable hollow microneedle sensing patches for the transdermal electrochemical monitoring of glucoseTalanta, 2022
- In vivo Microscopic Photoacoustic Spectroscopy for Non-Invasive Glucose Monitoring Invulnerable to Skin Secretion ProductsScientific Reports, 2018
- Characterization of micro-resonator based on enhanced metal insulator semiconductor capacitor for glucose recognitionMedical Engineering & Physics, 2017
- Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin InjectionsJAMA, 2017
- Non-invasive glucose monitoring technology in diabetes management: A reviewAnalytica Chimica Acta, 2012
- Noninvasive in vitro measurement of pig-blood d-glucose by using a microwave cavity sensorDiabetes Research and Clinical Practice, 2012
- Invasiveness as a Barrier to Self-Monitoring of Blood Glucose in DiabetesDiabetes Technology & Therapeutics, 2005
- Random ForestsMachine Learning, 2001