Detection of Multiple Sclerosis Biomarkers in Serum by Ganglioside Microarrays and Surface Plasmon Resonance Imaging
Authors:
- 28 October 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (11) , 3617-3626
Abstract
Multiple sclerosis (MS) is an autoimmune disease that damages the myelin sheaths of nerve cells in the central nervous system. An individual suffering from MS produces increased levels of antibodies that target cell membrane components, such as phospholipids, gangliosides, and membrane proteins. Among them, anti-ganglioside antibodies are considered as important biomarkers to differentiate MS from other diseases that exhibit similar symptoms. We report here a label-free method for detecting a series of antibodies against gangliosides in serum by surface plasmon resonance imaging (SPRi) in combination with a carbohydrate microarray. The ganglioside array was fabricated with a plasmonically tuned, background-free biochip, and coated with a perfluorodecyltrichlorosilane (PFDTS) layer for antigen attachment as a self-assembled pseudo-myelin sheath. The chip was characterized with AFM and matrix-assisted laser desorption ionization mass spectrometry, demonstrating effective functionalization of the surface. SPRi measurements of patients’ mimicking blood samples were conducted. A multiplexed detection of antibodies for anti-GT1b, anti-GM1, and anti-GA1 in serum was demonstrated, with a working range of 1 to 100 ng/mL, suggesting that it is well suited for clinical assessment of antibody abnormality in MS patients. Statistical analyses, including PLS-DA and PCA show the array allows comprehensive characterization of cross reactivity patterns between the MS specific antibodies and can generate a wide range of information compared to traditional end point assays. This work uses PFDTS surface functionalization and enables direct MS biomarker detection in serum, offering a powerful alternative for MS assessment and potentially improved patient care.Keywords
Funding Information
- National Institute of Allergy and Infectious Diseases (R21AI140461)
This publication has 45 references indexed in Scilit:
- Long-lived superhydrophobic surfacesJournal of Materials Chemistry A, 2012
- “Undiagnosing” multiple sclerosisNeurology, 2012
- Sensitivity comparison of surface plasmon resonance and plasmon-waveguide resonance biosensorsSensors and Actuators B: Chemical, 2011
- Patterned Resonance Plasmonic Microarrays for High-Performance SPR ImagingAnalytical Chemistry, 2011
- Label-free analysis of biomolecular interactions using SPR imagingBioTechniques, 2011
- On-Plate Desalting and SALDI-MS Analysis of Peptides with Hydrophobic Silicate Nanofilms on a Gold SubstrateAnalytical Chemistry, 2010
- Brain gangliosides in axon–myelin stability and axon regenerationFEBS Letters, 2009
- MALDI mass spectrometry imaging of gangliosides in mouse brain using ionic liquid matrixAnalytica Chimica Acta, 2009
- Recent advances in recording electrophysiological data simultaneously with magnetic resonance imagingNeuroImage, 2008
- Surface Plasmon Resonance Imaging Analysis of Protein-Receptor Binding in Supported Membrane Arrays on Gold Substrates with Calcinated Silicate FilmsJournal of the American Chemical Society, 2006