Data mining neocortical high-frequency oscillations in epilepsy and controls
Open Access
- 8 September 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in Brain
- Vol. 134 (10) , 2948-2959
Abstract
Transient high-frequency (100–500 Hz) oscillations of the local field potential have been studied extensively in human mesial temporal lobe. Previous studies report that both ripple (100–250 Hz) and fast ripple (250–500 Hz) oscillations are increased in the seizure-onset zone of patients with mesial temporal lobe epilepsy. Comparatively little is known, however, about their spatial distribution with respect to seizure-onset zone in neocortical epilepsy, or their prevalence in normal brain. We present a quantitative analysis of high-frequency oscillations and their rates of occurrence in a group of nine patients with neocortical epilepsy and two control patients with no history of seizures. Oscillations were automatically detected and classified using an unsupervised approach in a data set of unprecedented volume in epilepsy research, over 12 terabytes of continuous long-term micro- and macro-electrode intracranial recordings, without human preprocessing, enabling selection-bias-free estimates of oscillation rates. There are three main results: (i) a cluster of ripple frequency oscillations with median spectral centroid = 137 Hz is increased in the seizure-onset zone more frequently than a cluster of fast ripple frequency oscillations (median spectral centroid = 305 Hz); (ii) we found no difference in the rates of high frequency oscillations in control neocortex and the non-seizure-onset zone neocortex of patients with epilepsy, despite the possibility of different underlying mechanisms of generation; and (iii) while previous studies have demonstrated that oscillations recorded by parenchyma-penetrating micro-electrodes have higher peak 100–500 Hz frequencies than penetrating macro-electrodes, this was not found for the epipial electrodes used here to record from the neocortical surface. We conclude that the relative rate of ripple frequency oscillations is a potential biomarker for epileptic neocortex, but that larger prospective studies correlating high-frequency oscillations rates with seizure-onset zone, resected tissue and surgical outcome are required to determine the true predictive value.Keywords
This publication has 44 references indexed in Scilit:
- Unsupervised Classification of High-Frequency Oscillations in Human Neocortical Epilepsy and Control PatientsJournal of Neurophysiology, 2010
- Microseizures and the spatiotemporal scales of human partial epilepsyBrain, 2010
- Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronicsNature Materials, 2010
- A Conformal, Bio-Interfaced Class of Silicon Electronics for Mapping Cardiac ElectrophysiologyScience Translational Medicine, 2010
- Epilepsy surgery outcomes in temporal lobe epilepsy with a normal MRIEpilepsia, 2009
- Large-scale electrophysiology: Acquisition, compression, encryption, and storage of big dataJournal of Neuroscience Methods, 2009
- Phase I trial: safety and feasibility of intracranial electroencephalography using hybrid subdural electrodes containing macro- and microelectrode arraysNeurosurgical Focus, 2008
- High-frequency oscillations in human temporal lobe: simultaneous microwire and clinical macroelectrode recordingsBrain, 2008
- Human and automated detection of high-frequency oscillations in clinical intracranial EEG recordingsClinical Neurophysiology, 2007
- Reactivation of Hippocampal Ensemble Memories During SleepScience, 1994