Internal fixation devices, which can stabilize and realign fractured bone, are widely used in fracture management. In this paper, a biodegradable composite fixator, composed of poly(ε-caprolactone), calcium phosphate ceramic and calcium sulfate (PCL/CPC/CS), is developed. The composition of CS, which has a high dissolution rate, was expected to create a porous structure to improve osteofixation to the composite fixator. PCL, PCL/CPC, and PCL/CPC/CS samples were prepared and their physical properties were characterized in vitro. In vivo performance of the composite screws was verified in the distal femurs of rabbits. Results showed that the PCL/CPC/CS composite had a higher compressive strength (28.55 ± 3.32 MPa) in comparison with that of PCL (20.64 ± 1.81 MPa) (p < 0.05). A larger amount of apatite was formed on PCL/CPC/CS than on PCL/CPC, while no apatite was found on PCL after simulated body fluid immersion. In addition, PCL/CPC/CS composites also had a faster in vitro degradation rate (13.05 ± 3.42% in weight loss) relative to PCL (1.79 ± 0.23%) and PCL/CPC (4.32 ± 2.18%) (p < 0.001). In animal studies, PCL/CPC/CS screws showed a greater volume loss than that of PCL or PCL/CPC at 24 weeks post-implantation. Under micro-computerized tomography observation, animals with PCL/CPC/CS implants had better osseointegration in terms of the structural parameters of the distal metaphysis, including trabecular number, trabecular spacing, and connectivity density, than the PCL screw. This study reveals that the addition of CS accelerates the biodegradation and enhanced apatite formation of the PCL/CPC composite screw. This osteoconductive PCL/CPC/CS is a good candidate material for internal fixation devices.Keywords
Funding Information
- Ministry of Science and Technology (MOST103-2218-E-002-028)
- En Chu Kong Hospital (ECKH10401)
This publication has 46 references indexed in Scilit:
- Apatite Formation: Why It May Not Work as Planned, and How to Conclusively Identify Apatite CompoundsBioMed Research International, 2013
- Delayed foreign body reaction after fixation of distal radius fracture with biodegradable implantFormosan Journal of Musculoskeletal Disorders, 2012
- Tissue Restoration After Implantation of Polyglycolide, Polydioxanone, Polylevolactide, and Metallic Pins in Cortical Bone: An Experimental Study in RabbitsCalcified Tissue International, 2010
- Clinical application of a custom-made bioresorbable raw particulate hydroxyapatite/poly-l-lactide mesh tray for mandibular reconstructionOdontology, 2010
- Soluble ions more than particulate cobalt‐alloy implant debris induce monocyte costimulatory molecule expression and release of proinflammatory cytokines critical to metal‐induced lymphocyte reactivityJournal of Biomedical Materials Research Part A, 2009
- Biological performance of a polycaprolactone-based scaffold used as fusion cage device in a large animal model of spinal reconstructive surgeryBiomaterials, 2009
- Internal plate fixation of fractures: short history and recent developmentsJournal of Orthopaedic Science, 2006
- Fabrication of calcium sulfate/PLLA composite for bone repairJournal of Biomedical Materials Research Part A, 2005
- Are there any complications with bioabsorbable fixation devices?International Journal of Oral and Maxillofacial Surgery, 2004
- Response of a Calcium Sulfate Bone Graft Substitute in a Confined Cancellous DefectClinical Orthopaedics and Related Research, 2003