A Comparison of Hydrochloric Acid and Acetate Buffer Media for Trace Metal Analysis Using Sb-Film Electrodes: A Detailed Electrochemical Impedance Spectroscopy Study
Authors:
- 14 February 2019
- journal article
- research article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (4) , H108-H118
Abstract
The main focus of this work is a detailed electrochemical impedance spectroscopy (EIS) study at different potentials of an in situ-prepared antimony-film modified electrode (SbFE) in either 0.01 M HCl or 0.1 M acetate buffer solutions. No such detailed EIS study has been presented previously. First, method validation in terms of detection and quantification limits (LOD and LOQ respectively), linear concentration range, accuracy, and precision was performed for the bare glassy carbon electrode (GCE) and in situ-formed SbFE in both media employed in the determination of trace amounts of Zn(II), Cd(II), and Pb(II). Next, by means of EIS, the performance of these electrodes was explained by investigating the electrode's behavior at certain potentials that are crucial in anodic stripping voltammetry experiments. The method sensitivity was explained by the polarization resistance values obtained from the detailed EIS fitting procedure. Furthermore, a combination of charge-transfer-controlled and diffusion-controlled processes was taken into account. It was shown that the behavior of these electrodes strongly depends on the medium used, on the potential applied, and on the presence of certain species in the solution. Potentials of zero charge were also evaluated for the bare GCE and SbFEs in both solutions.Keywords
Funding Information
- The Slovenian Research and Innovation Agency (P2-0032, J1-9169)
This publication has 36 references indexed in Scilit:
- Disposable screen-printed antimony film electrode modified with carbon nanotubes/ionic liquid for electrochemical stripping measurementElectrochimica Acta, 2011
- Factors Controlling Stripping Voltammetry of Lead at Polycrystalline Boron Doped Diamond Electrodes: New Insights from High-Resolution MicroscopyAnalytical Chemistry, 2011
- Insights into the simultaneous chronopotentiometric stripping measurement of indium(III), thallium(I) and zinc(II) in acidic medium at the in situ prepared antimony film carbon paste electrodeElectrochimica Acta, 2010
- Antimony Film Microelectrode for Anodic Stripping Measurement of Cadmium(II), Lead(II) and Copper(II)Electroanalysis, 2010
- A Decade with Bismuth‐Based Electrodes in ElectroanalysisElectroanalysis, 2010
- Ex Situ Prepared Antimony Film Electrode for Electrochemical Stripping Measurement of Heavy Metal IonsElectroanalysis, 2009
- Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrodeElectrochimica Acta, 2009
- Determination of Sn2+ Ion in Canned Foods Using Bismuth- and Antimony-Film ElectrodesSensor Letters, 2009
- Linearity of calibration curves: use and misuse of the correlation coefficientAccreditation and Quality Assurance, 2002
- Bismuth-Coated Carbon Electrodes for Anodic Stripping VoltammetryAnalytical Chemistry, 2000