Risk stratification for implantable cardioverter defibrillator therapy: the role of the wearable cardioverter-defibrillator
Authors:
Open Access
- 31 May 2013
- journal article
- review article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 34 (29) , 2230-2242
Abstract
The benefit of implantable cardioverter-defibrillator (ICD) therapy depends upon appropriate evaluation of a persisting risk of sudden death and estimation of the patient's overall survival. Assessment of a stable and unchangeable arrhythmogenic substrate is often difficult. Structural abnormality and ventricular dysfunction, the two major risk parameters, may recover, and heart failure symptoms can improve so that ICD therapy may not be indicated. Risk stratification can take time while the patient continues to be at high risk of arrhythmic death, and patients may need temporary bridging by a defibrillator in cases of interrupted ICD therapy. The wearable cardioverter-defibrillator (WCD) combines a long-term electrocardiogram (ECG)-monitoring system with an external automatic defibrillator. The LIfeVest® (ZOLL, Pittsburgh, PA, USA) is composed of a garment, containing two defibrillation patch electrodes on the back, and an elastic belt with a front-defibrillation patch electrode and four non-adhesive ECG electrodes, connected to a monitoring and defibrillation unit. The WCD is a safe and effective tool to terminate ventricular tachycardia/ventricular fibrillation events, unless a conscious patient withholds shock delivery. It may be used in patients in the early phase after acute myocardial infarction with poor left ventricular function, after acute coronary revascularization procedures (percutaneous coronary intervention or coronary artery bypass grafting) and reduced left ventricular ejection fraction (≤35%), in patients with acute heart failure in non-ischaemic cardiomyopathy of uncertain aetiology and prognosis. The WCD may be helpful in subjects with syncope of assumed tachyarrhythmia origin or in patients with inherited arrhythmia syndromes. The WCD may replace ICD implantation in patients waiting for heart transplantation or who need a ventricular-assist device. This review describes the technical details and characteristics of the WCD, discusses its various potential applications, and reports the currently available experience with the wearable defibrillator.Keywords
This publication has 56 references indexed in Scilit:
- Reduction in Inappropriate Therapy and Mortality through ICD ProgrammingNew England Journal of Medicine, 2012
- Sudden cardiac death and implantable cardioverter defibrillators: two modern epidemics?EP Europace, 2012
- Non–Evidence-Based ICD Implantations in the United StatesJAMA, 2011
- Defibrillator Implantation Early after Myocardial InfarctionNew England Journal of Medicine, 2009
- ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesCirculation, 2008
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureNew England Journal of Medicine, 2005
- Prophylactic Use of an Implantable Cardioverter–Defibrillator after Acute Myocardial InfarctionNew England Journal of Medicine, 2004
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- A Comparison of Antiarrhythmic-Drug Therapy with Implantable Defibrillators in Patients Resuscitated from Near-Fatal Ventricular ArrhythmiasNew England Journal of Medicine, 1997
- Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular ArrhythmiaNew England Journal of Medicine, 1996