This paper presents a single phase, single stage on-board Plug-in Electric Vehicle (PEV) charger. The single phase PEV chargers have inherent problem of introducing second order ripple component on DC side. This problem is further exaggerated during vehicle-to-grid (V2G) mode of operation where it may be normally controlled to supply both active as well as reactive power. During the V2G reactive power compensation, the second order harmonics ripple component at DC side will increase which further reduces the life cycle and performance of battery pack. Therefore, a second order ripple component compensation technique is proposed by pre-compensating the reference current itself. The resultant reference current is periodic in nature and accordingly, repetitive controller (RC) is used which is well known for its capability of tracking the periodic signals. The PEV charger is controlled in both grid to vehicle (G2V) and V2G mode. Here, the performance of the controller has been tested in eight different modes on active-reactive (P-Q) power plane and found that ripple minimization technique successfully reduced second order ripple component on DC side. The PEV charger controller has been simulated in MATLAB/Simulink environment and implemented on the scaled down experimental setup.

This publication has 24 references indexed in Scilit: