Stereotactic biopsy of the breast using a decubitus table: comparison of histologic underestimation rates between 11- and 8-gauge vacuum-assisted breast biopsy
Open Access
- 22 October 2013
- journal article
- research article
- Published by Springer Nature in SpringerPlus
- Vol. 2 (1) , 551
Abstract
Purpose: To evaluate efficacy of the stereotactic vacuum-assisted breast biopsy(SVAB) using a decubitus table and to compare histologic underestimation rate between 11gauge(G)- and 8G-probes. Materials and methods: Pathologic results of SVAB using a decubitus table of 210(120 with 11G; 90 with 8G)-procedures in 208-women(median age, 48.8 years; range, 27-73 years) were retrospectively reviewed. SVAB was performed for suspicious microcalcification without mass on MMG and US. Surgury was performed for the diagnosis of malignant or high-risk lesion (65(31.0%)). Patients with benign diagnosis (120(57.1%)) underwent MMG follow-up (mean, 340-days). Histologic underestimation was defined as the need to upgrade ADH to DCIS or IDC, and DCIS to IDC at surgery. We analyzed the difference of procedure time, core number and core weight between 11G- and 8G-groups. Statistical significance was determined with chi-square test and 95%-CI for histologic underestimation, and student T-test for comparing two-groups. Results: Targeting was successful in all 210-biopsies on specimen radiographs. Mean core number, core weight and procedure time were 17.5 (17.5 ± 4.9), 1.57 g (1.57 ± 0.56), 34.5 min (34.5 ± 16.4) with 11G-probe, and 9.6 (9.6 ± 6.2), 1.83g (1.83 ± 0.93), 22.1 min (22.1 ± 12.5) with 8G-probe. Findings in 120 (57.1%) of the biopsies were benign, 36 (17.2%) were high-risk, and 54 (25.7%) were malignant. Two (6.25%) of 32 cases of ADH were upgraded to DCIS in 11G-group, and 2 (9.09%) of 22 in 8G-group. No case of DCIS was upgraded to IDC. There was no increase of complication in 8G-group than 11G-group. Conclusion: SVAB using a decubitus table is safe and effective method for the evaluation of suspicious microcalcification, and there was no significant difference between 11G- and 8G-probes. But, SVAB with 8G-probe is significantly more time efficient and effective procedure.Keywords
This publication has 28 references indexed in Scilit:
- Upright stereotactic vacuum-assisted needle biopsy of suspicious breast microcalcificationsJournal of Medical Imaging and Radiation Oncology, 2008
- Vacuum-assisted large-core needle biopsy (VLNB) improves the management of patients with breast microcalcifications – Analysis of 1009 casesEuropean Journal of Surgical Oncology, 2008
- Stereotactic Breast Biopsy: Comparison of Histologic Underestimation Rates with 11- and 9-Gauge Vacuum-Assisted Breast BiopsyAmerican Journal of Roentgenology, 2007
- Diagnostic performance of stereotactic large core needle biopsy for nonpalpable breast lesions in routine clinical practiceInternational Journal of Cancer, 2007
- Stereotactic vacuum-assisted breast biopsies in 500 women with microcalcifications: radiological and pathological correlationsEuropean Journal of Radiology, 2005
- Stereotactic vacuum-assisted breast biopsy in 2874 patients: A multicenter studyCancer, 2004
- Stereotactic vacuum‐assisted breast biopsy in 2874 patientsCancer, 2003
- Stereotactic Core-Needle Biopsy of Non-Mass Calcifications: Outcome and Accuracy at Long-Term Follow-UpKorean Journal of Radiology, 2003
- Stereotactic Biopsy of the Breast Using an Upright Unit, a Vacuum-Suction Needle, and a Lateral Arm-Support SystemAmerican Journal of Roentgenology, 2002
- Adaptation of an add-on stereotaxic breast biopsy unit: use of a dedicated reclinable mammography chair.American Journal of Roentgenology, 1997