Background: The Ki‐67 proliferation marker has multiple diagnostic and prognostic applications. Although several clones to the Ki‐67 antigen are commercially available, the MIB1 clone is widely recommended in the surgical pathology literature for neuroendocrine tumors. In our cytopathology practice, we have encountered unexpectedly low MIB1 immunoreactivity in CytoLyt‐fixed cell blocks (CBs). The current study evaluated the impact of fixatives, CB processing, and immunocytochemical (ICC) procedures on Ki‐67 immunoreactivity.Methods: Test CBs were prepared from freshly resected tumors, and multiple variables in the MIB1 ICC procedure were tested, including CytoLyt versus formalin collection media, MIB1 versus other Ki‐67 clones including 30‐9, and other variables. MIB1 versus Ki‐67 30‐9 clones were tested in parallel on CytoLyt‐fixed CBs from clinical samples of small cell lung carcinoma (SCLC).Results: In the test CBs (n = 10), the mean MIB1 labeling index was 10% in CytoLyt versus 47% in formalin (P = .0116), with a mean loss of reactivity in matched CBs of 37% (up to 70%). None of the procedure modifications tested in 223 individual ICC reactions recovered MIB1 reactivity in CytoLyt except for switching to the Ki‐67 30‐9 antibody. In CytoLyt‐fixed SCLC samples (n = 14), the Ki‐67 30‐9 antibody demonstrated expected ranges of reactivity (mean, 83%; range, 60%‐100%), whereas MIB1 demonstrated markedly inhibited labeling (mean, 60%; range, 10%‐95%) (P = .0058).Conclusions: CytoLyt fixation substantially inhibits MIB1 immunoreactivity, whereas the Ki‐67 30‐9 clone is not susceptible to inhibition. Markedly discrepant MIB1 reactivity may present a pitfall in the diagnosis of SCLC and may lead to the incorrect prognostic stratification of other tumor types. For laboratories using CytoLyt, we recommend using the Ki‐67 30‐9 antibody rather than the MIB1 antibody.Keywords
Funding Information
- National Cancer Institute (P30CA008748)
This publication has 25 references indexed in Scilit:
- Ki-67 Antigen in Lung Neuroendocrine Tumors: Unraveling a Role in Clinical PracticeJournal of Thoracic Oncology, 2014
- Utility of the Quantitative Ki-67 Proliferation Index and CD56 Together in the Cytologic Diagnosis of Small Cell Lung Carcinoma and Other Lung Neuroendocrine TumorsActa Cytologica, 2013
- New Pathologic Classification of Lung Cancer: Relevance for Clinical Practice and Clinical TrialsJournal of Clinical Oncology, 2013
- Ki67 and proliferation in breast cancerJournal of Clinical Pathology, 2013
- Cellient™ automated cell block versus traditional cell block preparation: A comparison of morphologic features and immunohistochemical stainingDiagnostic Cytopathology, 2010
- The Pathologic Classification of Neuroendocrine TumorsPancreas, 2010
- Immunohistochemical detection of estrogen receptor, progesterone receptor, and human epidermal growth factor receptor 2 expression in breast carcinomasCancer Cytopathology, 2009
- Review of meningioma histopathologyNeurosurgical Focus, 2007
- Immunohistochemical Staining of Cytologic Smears With MIB-1 Helps Distinguish Low-Grade From High-Grade Neuroendocrine NeoplasmsAmerican Journal of Clinical Pathology, 2003
- Immunocytochemistry of serous effusion specimens: A comparison of ThinPrep® vs. cell blockDiagnostic Cytopathology, 2002