Subspace-based technique for speckle noise reduction in ultrasound images
Open Access
- 1 January 2014
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 154
Abstract
Ultrasound imaging is a very essential technique in medical diagnosis due to its being safe, economical and non-invasive nature. Despite its popularity, the US images, however, are corrupted with speckle noise, which reduces US images qualities, hampering image interpretation and processing stage. Hence, there are many efforts made by researches to formulate various despeckling methods for speckle reduction in US images. In this paper, a subspace-based speckle reduction technique in ultrasound images is proposed. The fundamental principle of subspace-based despeckling technique is to convert multiplicative speckle noise into additive via logarithmic transformation, then to decompose the vector space of the noisy image into signal and noise subspaces. Image enhancement is achieved by nulling the noise subspace and estimating the clean image from the remaining signal subspace. Linear estimation of the clean image is derived by minimizing image distortion while maintaining the residual noise energy below some given threshold. The real US data for validation purposes were acquired under the IRB protocol (200210851-7) at the University of California Davis, which is also consistent with NIH requirements. Experiments are carried out using a synthetically generated B-mode ultrasound image, a computer generated cyst image and real ultrasound images. The performance of the proposed technique is compared with Lee, homomorphic wavelet and squeeze box filter (SBF) in terms of noise variance reduction, mean preservation, texture preservation and ultrasound despeckling assessment index (USDSAI). The results indicate better noise reduction capability with the simulated images by the SDC than Lee, Wavelet and SBF in addition to less blurry effect. With the real case scenario, the SDC, Lee, Wavelet and SBF are tested with images obtained from raw radio frequency (RF) data. Results generated using real US data indicate that, in addition to good contrast enhancement, the autocorrelation results shows better preservation of image texture by SDC than Lee, Wavelet and SBF. In general, the performance of the SDC filter is better than Lee, Wavelet and SBF in terms of noise reduction, improvement in image contrast and preservation of the autocorrelation profiles. Furthermore, the filter required less computational time compared to Lee, Wavelet and SBF, which indicates its suitability for real time application.Keywords
This publication has 30 references indexed in Scilit:
- Ultrasonic Imaging2006
- Bivariate shrinkage functions for wavelet-based denoising exploiting interscale dependencyIEEE Transactions on Signal Processing, 2002
- Real-time speckle reduction and coherence enhancement in ultrasound imaging via nonlinear anisotropic diffusionIEEE Transactions on Biomedical Engineering, 2002
- An adaptive KLT approach for speech enhancementIEEE Transactions on Speech and Audio Processing, 2001
- Novel Bayesian multiscale method for speckle removal in medical ultrasound imagesIEEE Transactions on Medical Imaging, 2001
- A novel multiscale nonlinear thresholding method for ultrasonic speckle suppressingIEEE Transactions on Medical Imaging, 1999
- Speckle reduction and contrast enhancement of echocardiograms via multiscale nonlinear processingIEEE Transactions on Medical Imaging, 1998
- A signal subspace approach for speech enhancementIEEE Transactions on Speech and Audio Processing, 1995
- An Alternative Form of the Lee Filter for Speckle Suppression in SAR ImagesGraphical Models and Image Processing, 1995
- Digital Image ProcessingLeonardo, 1981