Rotary piston blood pumps: past developments and future potential of a unique pump type
- 4 July 2016
- journal article
- review article
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 13 (8) , 759-771
Abstract
Introduction: The design of implantable blood pumps is either based on displacement pumps with membranes or rotary pumps. Both pump types have limitations to meet the clinical requirements. Rotary piston blood pumps have the potential to overcome these limitations and to merge the benefits. Compared to membrane pumps, they are smaller and with no need for wear-affected membranes and valves. Compared to rotary pumps, the blood flow is pulsatile instead of a non-physiological continuous flow. Furthermore, the risk of flow-induced blood damage and platelet activation may be reduced due to low shear stress to the blood. Areas covered: The past developments of rotary piston blood pumps are summarized and the main problem for long-term application is identified: insufficient seals. A new approach with seal-less drives is proposed and current research on a simplified rotary piston design is presented. Expert commentary: The development of blood pumps focuses mainly on the improvement of rotary pumps. However, medical complications indicate that inherent limitations of this pump type remain and restrict the next substantial step forward in the therapy of heart failure patients. Thus, research on different pump types is reasonable. If the development of reliable drives and bearings succeeds, rotary piston blood pumps become a promising alternative.Keywords
This publication has 24 references indexed in Scilit:
- Seventh INTERMACS annual report: 15,000 patients and countingThe Journal of Heart and Lung Transplantation, 2015
- Does pulsatility matter in the era of continuous-flow blood pumps?The Journal of Heart and Lung Transplantation, 2015
- Shear-Induced Hemolysis: Species DifferencesArtificial Organs, 2015
- Why pulsatility still matters: a review of current knowledgeCroatian Medical Journal, 2014
- Extracorporeal Membrane Oxygenation as a Bridge to Definite Surgery in Recurrent Postinfarction Ventricular Septal DefectASAIO Journal, 2012
- Response of Rotary Blood Pumps to Changes in Preload and Afterload at a Fixed Speed Setting Are Unphysiological When Compared With the Natural HeartArtificial Organs, 2011
- Postoperative Prophylactic Peritoneal Dialysis in Neonates and Infants After Complex Congenital Cardiac SurgeryASAIO Journal, 2006
- The Effects of Pulsatile Flow Upon Renal Tissue Perfusion During Cardiopulmonary Bypass: A Comparative Study of Pulsatile and Nonpulsatile FlowASAIO Journal, 2005
- Blood pumps for circulatory supportPerfusion, 2000
- Effect of Respiration on the Arterial Pressure Wave in Calves With Nonpulsatile Biventricular BypassASAIO Journal, 1994