Segmentation of thrombus in abdominal aortic aneurysms from CTA with nonparametric statistical grey level appearance modeling
Authors:
- S.D. OlabarriagaSOS.D. Olabarriaga
- J.-M. RouetJRJ.-M. Rouet
- M. FradkinMFM. Fradkin
- M. BreeuwerMBM. Breeuwer
- W.J. NiessenWNW.J. Niessen
- 4 April 2005
- journal article
- clinical trial
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 24 (4) , 477-485
Abstract
This paper presents a new method for deformable model-based segmentation of lumen and thrombus in abdominal aortic aneurysms from computed tomography (CT) angiography (CTA) scans. First the lumen is segmented based on two positions indicated by the user, and subsequently the resulting surface is used to initialize the automated thrombus segmentation method. For the lumen, the image-derived deformation term is based on a simple grey level model (two thresholds). For the more complex problem of thrombus segmentation, a grey level modeling approach with a nonparametric pattern classification technique is used, namely k-nearest neighbors. The intensity profile sampled along the surface normal is used as classification feature. Manual segmentations are used for training the classifier: samples are collected inside, outside, and at the given boundary positions. The deformation is steered by the most likely class corresponding to the intensity profile at each vertex on the surface. A parameter optimization study is conducted, followed by experiments to assess the overall segmentation quality and the robustness of results against variation in user input. Results obtained in a study of 17 patients show that the agreement with respect to manual segmentations is comparable to previous values reported in the literature, with considerable less user interaction.Keywords
This publication has 26 references indexed in Scilit:
- Interactive segmentation of abdominal aortic aneurysms in CTA imagesMedical Image Analysis, 2004
- Aortic Diameter Is an Insensitive Measurement of Early Aneurysm Expansion After EndograftingJournal of Endovascular Therapy, 2004
- Segmentation of Abdominal Aortic Aneurysms with a Non-parametric Appearance ModelLecture Notes in Computer Science, 2004
- Discriminant snakes for 3D reconstruction of anatomical organsMedical Image Analysis, 2003
- Adapting Active Shape Models for 3D Segmentation of Tubular Structures in Medical Images2003
- Active shape model segmentation with optimal featuresIEEE Transactions on Medical Imaging, 2002
- Efficient model-based quantification of left ventricular function in 3-D echocardiographyIEEE Transactions on Medical Imaging, 2002
- Automatic Analysis of the Left Ventricle in the Time Sequences of 3D Echo-Cardiographic Images2001
- General Object Reconstruction Based on Simplex MeshesInternational Journal of Computer Vision, 1999
- Deformable models in medical image analysis: a surveyMedical Image Analysis, 1996