Biomechanical Evaluation of the Dynamic Hip Screw With Two- and Four-Hole Side Plates
Authors:
- Donna L. WheelerDWDonna L. Wheeler
- Jill RiderJRJill Rider
- Brett BolhofnerBBBrett Bolhofner
- 1 June 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 14 (5) , 318-323
Abstract
To determine the biomechanical strength and stiffness of a dynamic hip screw (DHS; Synthes USA, Paoli, PA, U.S.A.) with a two-hole side-plate as compared with a four-hole side-plate design for the reconstruction of unstable three-part intertrochanteric fractures. Eight matched pairs of embalmed human femurs were tested in two modes: (a) 2,000 cycles of simulated physiologic loading; (b) test to failure. Laboratory. Simulated single leg stance using a simulated pelvic loading mechanism with abductor loading. Strain and displacement sensors were used to measure fragment shear and distraction and surface strain in the proximal side plate. Eight pairs of skeletonized embalmed cadaveric specimens were selected on the basis of femoral neck angle and absence of old fracture, anatomic anomaly, or pathology. The specimens were divided into two groups: (a) left femurs received the two-hole side-plate design; (b) right femurs received the four-hole side-plate design. All fractures were reconstructed by the same surgeon using the manufacturer's instructions. Implant placement was verified by radiographic measurement of tip-to-apex distance. In cyclic testing, the amount of femoral neck fragment migration in both distraction and shear was quantified. Strain magnitude in the side plate was measured in both cyclic and failure testing. The peak load withstood by the reconstruction was quantified in the failure test. Peak load in the failure test was not found to be statistically different between the two-hole and four-hole designs. In cyclic testing, the two-hole configuration exhibited statistically smaller fragment migration in both shear and distraction than the four-hole design (p < 0.05). The strain magnitude in the side plate was not statistically different in the cyclic or failure tests. The femurs with a greater neck angle failed by crushing of the bone in the neck. The femurs with a lesser neck angle failed due to bending of the hardware. The results of this investigation revealed that the two-hole DHS is biomechanically as stable as the four-hole DHS in cyclic and failure loads under the conditions tested. These results, in concert with clinical experience, can be used to support the use of the two-hole DHS for the reconstruction of intertrochanteric fractures without a diaphyseal extension.Keywords
This publication has 13 references indexed in Scilit:
- Periprosthetic bone remodelling after cementless total hip replacementThe Journal of Bone and Joint Surgery. British volume, 1997
- Weight Bearing After Hip Fracture: A Prospective Series of 596 Geriatric Hip Fracture PatientsJournal of Orthopaedic Trauma, 1996
- Patients With Femoral Neck and Intertrochanteric FracturesClinical Orthopaedics and Related Research, 1996
- Fixation of intracapsular femoral neck fractures with a one-hole plate dynamic hip screwInjury, 1996
- How to minimize failures of fixation of unstable intertrochanteric fracturesInjury, 1995
- The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip.Journal of Bone and Joint Surgery, 1995
- Functional outcome after intertrochanteric fractures of the femur: does the implant matter? A prospective study of 100 consecutive casesInjury, 1993
- A BIOMECHANICAL EVALUATION OF AN INTRAMEDULLARY FIXATION DEVICE FOR INTERTROCHANTERIC FRACTURES1993
- Valgus reduction of trochanteric fracturesInjury, 1993
- Anteversion of the Acetabulum and Femoral Neck in Normals and in Patients with Osteoarthritis of the HipActa Orthopaedica, 1983