Fabrication of Microbolometer Arrays Based on Polymorphous Silicon–Germanium
Authors:
- Ricardo JimenezRJRicardo Jimenez
- Mario MorenoMario Moreno
- Alfonso TorresAlfonso Torres
- Alfredo MoralesAMAlfredo Morales
- Arturo PonceAPArturo Ponce
- Daniel FerruscaDFDaniel Ferrusca
- Jose Rangel-MagdalenoJose Rangel-Magdaleno
- Jorge Castro-RamosJCJorge Castro-Ramos
- Julio Hernandez-PerezJHJulio Hernandez-Perez
- Eduardo CanoECEduardo Cano
Open Access
Abstract
This work reports the development of arrays of infrared sensors (microbolometers) using a hydrogenated polymorphous silicon–germanium alloy (pm-SixGe1-x:H). Basically, polymorphous semiconductors consist of an amorphous semiconductor matrix with embedded nanocrystals of about 2–3 nm. The pm-SixGe1-x:H alloy studied has a high temperature coefficient of resistance (TCR) of 4.08%/K and conductivity of 1.5 × 10−5 S∙cm−1. Deposition of thermosensing film was made by plasma-enhanced chemical vapor deposition (PECVD) at 200 °C, while the area of the devices is 50 × 50 μm2 with a fill factor of 81%. Finally, an array of 19 × 20 microbolometers was packaged for electrical characterization. Voltage responsivity values were obtained in the range of 4 × 104 V/W and detectivity around 2 × 107 cm∙Hz1/2/W with a polarization current of 70 μA at a chopper frequency of 30 Hz. A minimum value of 2 × 10−10 W/Hz1/2 noise equivalent power was obtained at room temperature. In addition, it was found that all the tested devices responded to incident infrared radiation, proving that the structure and mechanical stability are excellent.Keywords
Funding Information
- Secretaría de Ciencia, Humanidades, Tecnología e Innovación (PUE-2018-03-02-84557)
This publication has 36 references indexed in Scilit:
- Quantitative study of the temperature dependence of normal LWIR apparent emissivityInfrared Physics & Technology, 2013
- A plastic-based bolometer array sensor using carbon nanotubes for low-cost infrared imaging devicesSensors and Actuators A: Physical, 2013
- Nanostructured vanadium oxide thin film with high TCR at room temperature for microbolometerInfrared Physics & Technology, 2013
- Light induced electrical and macroscopic changes in hydrogenated polymorphous silicon solar cellsEPJ Photovoltaics, 2012
- Study of performance degradation in Titanium microbolometer IR detectors due to elevated heatingInfrared Physics & Technology, 2011
- Polymorphous silicon thin films produced in dusty plasmas: application to solar cellsPlasma Physics and Controlled Fusion, 2004
- Comparison of transport and defects properties in hydrogenated polymorphous and amorphous siliconJournal of Non-Crystalline Solids, 2002
- MgO sacrificial layer for micromachining uncooled Y-Ba-Cu-O IR microbolometers on Si/sub 3/N/sub 4/ bridgesJournal of Microelectromechanical Systems, 1999
- Characterization and optimization of infrared poly SiGe bolometersIEEE Transactions on Electron Devices, 1999