A prospective comparative assessment of the accuracy of the FibroScan in evaluating liver steatosis
Open Access
- 15 August 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (8) , e0182784
Abstract
Recent studies have demonstrated the utility of the FibroScan® device in diagnosing liver steatosis, but its usefulness has not been thoroughly appraised. We investigated the usefulness of the controlled attenuation parameter (CAP) in detecting and quantifying liver steatosis. A prospective analysis was applied to 79 chronic liver disease patients who underwent a liver biopsy, a FibroScan investigation, ultrasonography, and hepatic steatosis index (HSI). The presence and degree of steatosis as measured by the FibroScan device, ultrasonography and HSI were compared with the results for the liver biopsy tissue. There was substantial concordance between the liver biopsy results and the CAP as evaluated by the kappa (κ) index test for detecting liver steatosis (κCAP = 0.77, Pultrasonography = 0.60, PHSI = 0.47, P<0.001). The areas under the receiver operating characteristic curve (AUROCs) of the CAP, ultrasonography, and HSI were 0.899 [95% confidence interval (CI) = 0.826–0.972)], 0.859 (95% CI = 0.779–0.939), and 0.766 (95% CI = 0.655–0.877), respectively. The optimal CAP cutoff value for differentiating between normal and hepatic steatosis was 247 dB/m, which produced sensitivity and specificity values of 91.9% and 85.7%, respectively, as well as a positive predictive value of 85.0% and a negative predictive value of 92.3%. The CAP produces results that are highly concordant with those of a liver biopsy in detecting steatosis. Therefore, the CAP is a noninvasive and reliable tool for evaluating liver steatosis, even in the early stages.Keywords
Funding Information
- Soonchunhyang University (KR) (20130614)
This publication has 41 references indexed in Scilit:
- Liver biopsy†Hepatology, 2009
- Utilization rates, complications and costs of percutaneous liver biopsy: a population‐based study including 4275 biopsiesLiver International, 2008
- Interobserver and Intraobserver Variability in the Sonographic Assessment of Fatty LiverAmerican Journal of Roentgenology, 2007
- Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver diseaseGut, 2007
- Nonalcoholic Fatty Liver Disease: From Steatosis to CirrhosisHepatology, 2006
- Hepatic MRI for Fat QuantitationJournal of Clinical Gastroenterology, 2005
- Design and validation of a histological scoring system for nonalcoholic fatty liver disease†Hepatology, 2005
- The histological course of nonalcoholic fatty liver disease: a longitudinal study of 103 patients with sequential liver biopsiesJournal of Hepatology, 2005
- Effect of Treatment With Peginterferon or Interferon Alfa–2B and Ribavirin on Steatosis in Patients Infected With Hepatitis CHepatology, 2003
- Prospective evaluation of the diagnostic accuracy of liver ultrasonography.Gut, 1981