A comparison of the outcome using Ligasure™ small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study
- 13 January 2015
- journal article
- research article
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 400 (2) , 247-252
Abstract
Hypoparathyroidism and paralysis of the recurrent laryngeal nerve (RLN) still remain the most frequent specific complications of thyroid surgery. This study evaluates the effects of employment of a recently introduced device (LigaSure™ Small Jaw, LSJ), compared to the traditional clamp-and-tie (CT) technique, on the short- and long-term outcome of the patients who underwent thyroidectomy. This prospective, randomized study included 190 patients enrolled from October 2011 to July 2013. The numbers of patients in the LSJ group and the CT group were both 95. We studied the following: operative times, intraoperative and postoperative blood losses, intact parathormone (iPTH) and calcium serum levels, and the incidence of RLN paralysis. The two cohorts were homogeneous for age, sex, surgical indication, BMI, ASA score, and estimated thyroid volume. Operation time has been 73.90 ± 23.35 min in group CT and 60.20 ± 22.36 min in group LSJ (p = 0.002). Intraoperative blood losses have been 47 ± 18 ml in group CT and 38 ± 14 in group LSJ (p = 0.002), while postoperative blood losses have been 45 ± 21 ml in group CT and 40 ± 20 in group LSJ (p = 0.105). The mean calcium blood level in group CT has been 8.12, 7.79, and 7.92 mg/dl in the first, second, and third postoperative days, respectively, as well as 8.26, 7.97, and 8.22 mg/dl for group LSJ (p > 0.05). Basal and post-thyroidectomy iPTH levels have been 46.49 and 23.64 pg/ml in group CT (Δ = 49.15 %), as well as 51.06 and 27.73 (Δ = 45.69 %) in group LSJ (p > 0.05). Permanent RLN paralysis was 1.05 % in LSJ group and 0 % in CT group. The employment of LSJ reduces in a statistically significant way both operative times and intraoperative blood losses. No significant differences were found as far as postoperative RLN paralysis and hypoparathyroidism.Keywords
This publication has 24 references indexed in Scilit:
- New technique using an energy-based device versus conventional technique in open thyroidectomyAuris Nasus Larynx, 2013
- Which Hemostatic Device in Thyroid Surgery? A Network Meta-Analysis of Surgical TechnologiesThyroid®, 2013
- Postoperative laryngoscopy in thyroid surgery: proper timing to detect recurrent laryngeal nerve injuryLangenbeck's Archives of Surgery, 2009
- Bipolar thermofusion vessel sealing system (TVS) versus conventional vessel ligation (CVL) in thyroid surgery—results of a prospective studyLangenbeck's Archives of Surgery, 2009
- Measuring Thyroid Gland Volume: Should We Change the Correction Factor?American Journal of Roentgenology, 2006
- Use of Ligasure in Thyroidectomy Procedures: Results of a Prospective Comparative StudyWorld Journal of Surgery, 2005
- Use of the Electrothermal Vessel Sealing System Versus Standard Vessel Ligation in ThyroidectomyAsian Journal of Surgery, 2005
- LigaSure versus clamp‐and‐tie thyroidectomy for benign nodular diseaseHead & Neck, 2004
- Évaluation de l’utilisation du dissecteur ultrasonique Ultracision® en chirurgie thyroïdienne. Étude prospective randomiséeAnnales de Chirurgie, 2000
- High-burst-strength, feedback-controlled bipolar vessel sealingSurgical Endoscopy, 1998