Metrology for Radiological Early Warning Networks in Europe (“METROERM”)—A Joint European Metrology Research Project
Authors:
- Harald DombrowskiHDHarald Dombrowski
- Patrick KesslerPKPatrick Kessler
- 1 August 2016
- journal article
- Published by Wolters Kluwer Health in Health Physics
- Vol. 111 (2) , 100-105
Abstract
As a consequence of the Chernobyl nuclear power plant accident in 1986, all European countries have installed automatic dosimetry network stations as well as air sampling systems for the monitoring of airborne radioactivity. In Europe, at present, almost 5,000 stations measure dose rate values in nearly real time. In addition, a few hundred air samplers are operated. Most of them need extended accumulation times with no real-time capability. National dose rate data are provided to the European Commission (EC) via the EUropean Radiological Data Exchange Platform (EURDEP). In case of a nuclear emergency with transboundary implications, the EC may issue momentous recommendations to EU member states based on the radiological data collected by EURDEP. These recommendations may affect millions of people and could have severe economic and sociological consequences. Therefore, the reliability of the EURDEP data is of key importance. Unfortunately, the dose rate and activity concentration data are not harmonized between the different networks. Therefore, within the framework of the European Metrology Research Programme (EMRP), 16 European institutions formed the consortium MetroERM with the aim to improve the metrological foundation of measurements and to introduce a pan-European harmonization for the collation and evaluation of radiological data in early warning network systems. In addition, a new generation of detector systems based on spectrometers capable of providing both reliable dose rate values as well as nuclide specific information in real time are in development. The MetroERM project and its first results will be presented and discussed in this article.Keywords
This publication has 6 references indexed in Scilit:
- EURADOS intercomparisons and the harmonisation of environmental radiation monitoringRadiation Protection Dosimetry, 2014
- Area dose rate values derived from NaI or LaBr3 spectraRadiation Protection Dosimetry, 2014
- Tracking of Airborne Radionuclides from the Damaged Fukushima Dai-Ichi Nuclear Reactors by European NetworksEnvironmental Science & Technology, 2011
- Traceability of the PTB low-dose rate photon calibration facilityRadiation Protection Dosimetry, 2010
- X-ray and gamma-ray response of a 2″×2″ LaBr3:Ce scintillation detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- The PTB underground laboratory for dosimetry and spectrometryApplied Radiation and Isotopes, 2000