Initial experience with LVIS TM EVO TM for distal flow diverting effects
- 11 November 2025
- journal article
- Published by SAGE Publications in Interventional Neuroradiology
Abstract
Background: Flow diversion for intracranial aneurysms is indicated for wide-necked aneurysms in non-perforator-rich segments. However, devices are challenging to deploy in distal/tortuous vasculature. LVIS TM EVO TM is a braided intermediate-density stent offering greater flexibility and navigability than flow diverters with higher metal-to-surface ratios. We investigated its off-label use as an independent flow diverter for small, complex intracranial aneurysms. Methods: We retrospectively reviewed patients at a single center who underwent independent stenting with LVIS TM EVO TM from December 2023 to September 2024. Demographics, procedural details, and angiographic outcomes were analyzed. Follow-up computed tomography angiography was performed from May 2024 to October 2025. Descriptive statistics were used; non-parametric tests compared aneurysm and parent vessel diameters. Results: Nine patients (median age 59; 89% female) with off-label intracranial aneurysms (median diameter 5 mm) were treated using LVIS TM EVO TM (median diameter 3 mm, length 18 mm). Deployment was technically successful in 100% of cases with no peri-procedural complications. One patient experienced delayed hemorrhage with full neurological recovery. At follow-up (available for 6 patients), 83.3% showed complete aneurysm occlusion (Raymond-Roy Occlusion Classification [RROC] class I). All patients demonstrated 100% stent patency and no new neurological deficits. Conclusion: LVIS TM EVO TM demonstrated technical feasibility and acceptable initial safety as an off-label flow-diverting device for small (as low as 2.5 mm), distal aneurysms in this limited single-center experience. Its favorable deliverability, safety profile, and occlusion rates suggest it as a possible alternative to currently marketed flow diverters in anatomically challenging patients. These findings warrant validation in larger, multicenter studies with extended follow-up.Keywords
This publication has 37 references indexed in Scilit:
- Flow Diversion for the Treatment of Intracranial AneurysmsJAMA Neurology, 2016
- Surpass Flow Diverter in the Treatment of Intracranial Aneurysms: A Prospective Multicenter StudyAmerican Journal of Neuroradiology, 2014
- The Pipeline embolization device for treatment of intracranial aneurysmsExpert Review of Medical Devices, 2013
- Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical TrialRadiology, 2013
- New Generation of Flow Diverter (Surpass) for Unruptured Intracranial AneurysmsStroke, 2013
- The Varying Porosity of Braided Self-Expanding Stents and Flow Diverters: An Experimental StudyAmerican Journal of Neuroradiology, 2012
- Impact of Stents and Flow Diverters on Hemodynamics in Idealized Aneurysm ModelsJournal of Biomechanical Engineering, 2011
- Flow diverters for treatment of intracranial aneurysms: Current status and ongoing clinical trialsJournal of Clinical Neuroscience, 2011
- The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms TrialAmerican Journal of Neuroradiology, 2010
- Indications for the Performance of Intracranial Endovascular Neurointerventional ProceduresCirculation, 2009