Neonatologist-Performed Echocardiography versus Pediatric Cardiologist for the Patent Ductus Arteriosus in Preterm Newborns
Open Access
- 2 May 2025
- journal article
- Published by Caleo in Turkish Archives of Pediatrics
- Vol. 60 (3) , 274-279
Abstract
Objective: Premature babies have a fragile circulatory system balance; therefore, rapid intervention may be needed in patients with patent ductus arteriosus (PDA). Echocardiography performed by a neonatologist can help to choose the best treatment option for newborns in a timely manner. The aim is to evaluate the performance of neonatologists in ductus assessment. Materials and Methods: Among the neonates born at the hospital, those diagnosed with PDA (n = 40) under 32 weeks of gestational age were evaluated with echocardiography by a neonatologist and a pediatric cardiologist. Interobserver variability analysis was done using the intraclass coefficient value and Cohen’s kappa test results. Results: An excellent interobserver agreement was found in the peak systolic-to-end diastolic flow velocity ratio, a good agreement in the narrowest diameter of the ductus, peak systolic and diastolic velocities, and mitral A velocity. Raters had moderate to poor agreement in the rest of the variables such as left atrium/aorta ratio, ampulla diameter, length of the ductus, and left pulmonary artery diameter. Conclusion: It is suggested that neonatologists perform echocardiography to measure the narrowest diameter of the ductus and ductal flow velocities for PDA evaluation. Cite this article as: Beyazal M, Hosagasi NH, Torun EG, Bagrul D, Kurt A. Neonatologist-performed echocardiography versus pediatric cardiologist for the patent ductus arteriosus in preterm newborns. Turk Arch Pediatr. 2025;60(3):274-279.Keywords
This publication has 22 references indexed in Scilit:
- Neonatologist-performed point-of-care functional echocardiography in the neonatal intensive care unitSingapore Medical Journal, 2017
- Recent Advances in the Treatment of Preterm Newborn Infants with Patent Ductus ArteriosusClinics in Perinatology, 2016
- Peak systolic to end diastolic flow velocity ratio is associated with ductal patency in infants below 32 weeks of gestationArchives of Disease in Childhood - Fetal and Neonatal Edition, 2014
- Targeted Neonatal Echocardiography ServicesJournal of Ultrasound in Medicine, 2014
- Cardiac Sonography by the NeonatologistJournal of Ultrasound in Medicine, 2014
- Early colour Doppler duct diameter and symptomatic patent ductus arteriosus in a cyclo‐oxygenase inhibitor naïve populationActa Paediatrica, 2013
- Early echocardiographic prediction of ductal closure in neonates ⩽30 weeks gestationJournal of Perinatology, 2012
- Interrater reliability: the kappa statisticBiochemia Medica, 2012
- Echocardiography predicts closure of patent ductus arteriosus in response to ibuprofen in infants less than 28week gestational ageEarly Human Development, 2010
- Echocardiographic assessment of patent ductus arteriosus shunt flow pattern in premature infantsArchives of Disease in Childhood - Fetal and Neonatal Edition, 1997