Scaling oxygen mass transfer in agitated fermentors

Author:

Abstract
There are many scaling formulas that predict the oxygen mass transfer coefficient as kL·a = constant·(Hp/V)αVsβ Exponents α and β frequently are scale dependent themselves. A general formula has been derived from the work of Calderbank,1 Miller,2 and Tilton,3 resulting in kL·a = C1 ϕ + C2 log (Pm/V) ϕ where ϕ equals the gas‐holdup fraction and Pm/V equals the effective mechanical power input per unit of volume. This formula is consistent with the formula of Westerterp4 modified by Miller.2 Gas holdup can be predicted in several ways. Gas‐sparged isothermal expansion power input, used for predicting ϕ, demonstrates that scaling can be done by using either superficial air velocity or volume per volume per minute for aeration.The importance of mixing in replenishing oxygen at the boundary layers of microorganisms will be assessed and compared with the kL·a as the oxygen transfer ratelimiting step.

This publication has 7 references indexed in Scilit: