Optimization of SPECT/CT imaging protocols for quantitative and qualitative 99mTc SPECT
Authors:
Open Access
- 30 July 2021
- journal article
- research article
- Published by Springer Nature in EJNMMI Physics
- Vol. 8 (1) , 1-14
Abstract
Background: The introduction of hybrid SPECT/CT devices enables quantitative imaging in SPECT, providing a methodological setup for quantitation using SPECT tracers comparable to PET/CT. We evaluated a specific quantitative reconstruction algorithm for SPECT data using a 99mTc-filled NEMA phantom. Quantitative and qualitative image parameters were evaluated for different parametrizations of the acquisition and reconstruction protocol to identify an optimized quantitative protocol. Results: The reconstructed activity concentration (ACrec) and the signal-to-noise ratio (SNR) of all examined protocols (n = 16) were significantly affected by the parametrization of the weighting factor k used in scatter correction, the total number of iterations and the sphere volume (all, p < 0.0001). The two examined SPECT acquisition protocols (with 60 or 120 projections) had a minor impact on the ACrec and no significant impact on the SNR. In comparison to the known AC, the use of default scatter correction (k = 0.47) or object-specific scatter correction (k = 0.18) resulted in an underestimation of ACrec in the largest sphere volume (26.5 ml) by − 13.9 kBq/ml (− 16.3%) and − 7.1 kBq/ml (− 8.4%), respectively. An increase in total iterations leads to an increase in estimated AC and a decrease in SNR. The mean difference between ACrec and known AC decreased with an increasing number of total iterations (e.g., for 20 iterations (2 iterations/10 subsets) = − 14.6 kBq/ml (− 17.1%), 240 iterations (24i/10s) = − 8.0 kBq/ml (− 9.4%), p < 0.0001). In parallel, the mean SNR decreased significantly from 2i/10s to 24i/10s by 76% (p < 0.0001). Conclusion: Quantitative SPECT imaging is feasible with the used reconstruction algorithm and hybrid SPECT/CT, and its consistent implementation in diagnostics may provide perspectives for quantification in routine clinical practice (e.g., assessment of bone metabolism). When combining quantitative analysis and diagnostic imaging, we recommend using two different reconstruction protocols with task-specific optimized setups (quantitative vs. qualitative reconstruction). Furthermore, individual scatter correction significantly improves both quantitative and qualitative results.Keywords
Funding Information
- Universitätsklinikum Magdeburg
This publication has 38 references indexed in Scilit:
- Improving quantitative dosimetry in 177Lu-DOTATATE SPECT by energy window-based scatter correctionsNuclear Medicine Communications, 2014
- Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modalityEuropean Journal of Nuclear Medicine and Molecular Imaging, 2013
- An Evidence-Based Review of Quantitative SPECT Imaging and Potential Clinical ApplicationsJournal of Nuclear Medicine, 2013
- MIRD Pamphlet No. 23: Quantitative SPECT for Patient-Specific 3-Dimensional Dosimetry in Internal Radionuclide TherapyJournal of Nuclear Medicine, 2012
- Review and current status of SPECT scatter correctionPhysics in Medicine & Biology, 2011
- Comparison of 10 versus 20 min SPECT 99mTc-MDP bone scansNuclear Medicine Communications, 2010
- Quantitative Accuracy of Clinical 99mTc SPECT/CT Using Ordered-Subset Expectation Maximization with 3-Dimensional Resolution Recovery, Attenuation, and Scatter CorrectionJournal of Nuclear Medicine, 2010
- Experimental determination of the weighting factor for the energy window subtraction-based downscatter correction for I-123 in brain SPECT studiesJournal of Medical Physics, 2010
- Quantitative SPECT reconstruction using CT-derived correctionsPhysics in Medicine & Biology, 2008
- A practical method for position-dependent Compton-scatter correction in single photon emission CTIEEE Transactions on Medical Imaging, 1991