Innovative optimization of greater omentum imaging report and data system for enhanced risk stratification of omental lesions
Open Access
- 10 March 2025
- journal article
- Published by Springer Nature in Cancer Imaging
- Vol. 25 (1) , 28
Abstract
Background: In 2020, we introduced the Greater Omentum Imaging-Reporting and Data System (GOI-RADS), a novel classification system related to peritoneal lesions. However, its clinical application remained unvalidated. Objective: This study aimed to validate GOI-RADS, optimize its parameters for a new grading system, and explore its clinical usefulness. Methods: A retrospective-prospective study was conducted to validate and refine the GOI-RADS system. The study consisted of two phases: a retrospective validation phase and a prospective application phase. The first phase included patients with peritoneal lesions from 2019 to 2021, classified by GOI-RADS and verified against pathology. Contrast-enhanced ultrasound (CEUS) and real-time elastography (RTE) data were collected for developing a new grading system. Odds ratios optimized parameters. The second phase (2021–2024) assessed diagnostic consistency among sonographers and performance of grading systems. Results: Among 215 patients with peritoneal lesions, the actual malignancy rates for GOI-RADS 2 (40.00%) and GOI-RADS 3 (61.22%) were much higher than predicted (5.56% and 37.25%). Combining CEUS and RTE parameters showed varying sensitivity and specificity: RTE + GOI-RADS (95.35%, 55.56%) and CEUS + GOI-RADS (96.51%, 44.44%). However, the grading system based on multiple ultrasound parameters, specifically when incorporating RTE, CEUS parameters, and GOI-RADS (Multi-GOIRADS), exhibited the highest diagnostic sensitivity and specificity of 88.37% and 83.33%, respectively. Its simplified version, sMulti-GOIRADS, had sensitivity of 73.26% and specificity of 94.44%. In the prospective study involving three sonographers of different qualifications, the use of sMulti-GOIRADS was found to be the most time-efficient and showed excellent diagnostic consistency among them. In contrast, Multi-GOIRADS required more time for scoring but offered superior diagnostic performance, particularly among senior sonographers (88.35% and 91.43%). Conclusions: This study proposes a multiparametric ultrasound-based imaging-reporting and data system for risk stratification of omental malignancy, Multi-GOIRADS, and presents an optimized and simplified version, sMulti-GOIRADS, which demonstrates excellent diagnostic consistency and performance in clinical applications.Keywords
This publication has 18 references indexed in Scilit:
- Exosomes secreted by ST3GAL5high cancer cells promote peritoneal dissemination by establishing a premetastatic microenvironmentMolecular Oncology, 2023
- Single-cell sequencing of ascites fluid illustrates heterogeneity and therapy-induced evolution during gastric cancer peritoneal metastasisNature Communications, 2023
- A Practical CEUS Thyroid Reporting System for Thyroid NodulesRadiology, 2022
- Radiology of the MesenteryClinics in Colon and Rectal Surgery, 2022
- Increase in the incidence of synchronous and metachronous peritoneal metastases in patients with colorectal cancer: A nationwide studyEuropean Journal of Surgical Oncology, 2021
- Synchronous peritoneal metastases of gastric cancer origin: incidence, treatment and survival of a nationwide Dutch cohortGastric Cancer, 2021
- Site of Recurrence and Survival After Surgery for Colorectal Peritoneal MetastasisJNCI: Journal of the National Cancer Institute, 2021
- Predictive value of omental thickness on ultrasonography for diagnosis of unexplained ascites, an Egyptian centre studyAsian Journal of Surgery, 2020
- Ultrasound Elastography for Differentiating Benign from Malignant Thickened Greater OmentumEuropean Radiology, 2015
- Peritoneal metastases: evaluation with contrast-enhanced ultrasoundAbdominal Radiology, 2010