Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults
- 11 August 2009
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 25 (1) , 118-130
Abstract
This paper presents a new control strategy for the rotor-side converter (RSC) of wind turbines (WTs) based on doubly fed induction generators (DFIG) that intends to improve its low-voltage ride through capability. The main objective of this work is to design an algorithm that would enable the system to control the initial overcurrents that appear in the generator during voltage sags, which can damage the RSC, without tripping it. As a difference with classical solutions, based on the installation of crowbar circuits, this operation mode permits to keep the inverter connected to the generator, something that would permit the injection of power to the grid during the fault, as the new grid codes demand. A theoretical study of the dynamical behavior of the rotor voltage is also developed, in order to show that the voltage at the rotor terminals required for the control strategy implementation remains under controllable limits. In order to validate the proposed control system simulation, results have been collected using PSCAD/EMTDC and experimental tests have been carried out in a scaled prototype.Keywords
This publication has 35 references indexed in Scilit:
- Coordinated Control of DFIG's Rotor and Grid Side Converters During Network UnbalanceIEEE Transactions on Power Electronics, 2008
- Two-Level VSC Based Predictive Direct Torque Control of the Doubly Fed Induction Machine With Reduced Torque and Flux Ripples at Low Constant Switching FrequencyIEEE Transactions on Power Electronics, 2008
- Advanced grid requirements for the integration of wind farms into the Spanish transmission systemIET Renewable Power Generation, 2008
- Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage DipsIEEE Transactions on Energy Conversion, 2007
- Ride-Through Analysis of Doubly Fed Induction Wind-Power Generator Under Unsymmetrical Network DisturbanceIEEE Transactions on Power Systems, 2006
- Control of a Doubly Fed Induction Generator in a Wind Turbine During Grid Fault Ride-ThroughIEEE Transactions on Energy Conversion, 2006
- Direct Active and Reactive Power Control of DFIG for Wind Energy GenerationIEEE Transactions on Energy Conversion, 2006
- Effect of low voltage ride through (LVRT) characteristic on voltage stability2005
- Ridethrough of Wind Turbines with Doubly-Fed Induction Generator During a Voltage DipIEEE Transactions on Energy Conversion, 2005
- Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditionsIEEE Transactions on Industry Applications, 2002