Outcomes of revision total hip arthroplasty using the modular dual mobility acetabular system to treat recurrent dislocation
Authors:
- 22 January 2022
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (4) , 789-795
Abstract
Background Recurrent dislocation is a difficult complication after total hip arthroplasty (THA). This study aimed to report the clinical and radiographic outcomes of revision THA using the modular dual mobility (MDM) acetabular system to treat recurrent dislocation. Methods Between March 2015 and February 2019, 34 revision THAs were performed using the MDM system for treating recurrent dislocation in a single institution. Of these, 32 revision THAs (32 patients) that satisfied a minimum follow-up of one year (mean, 4 years) were included in this study. Patient-reported outcomes, complication rates, and radiographic results were evaluated. Results Seventeen patients (53.1%) had lumbar degenerative kyphosis, and six (18.8%) had surgically fused lumbar spines during the index operation. All acetabular components were revised, whereas femoral stems were retained in 29 patients (90.6%). No redislocation or intraprosthetic dislocation was noted after revision. One additional revision was required for acetabular loosening with periprosthetic joint infection. No additional revision was performed for aseptic loosening. A partial radiolucent line was found in two hips (6.3%) confined to one acetabular zone. Conclusions Revision THA using the MDM system was effective in treating recurrent dislocation in a group of patients with a high prevalence of lumbar spinal pathology. During a mean follow-up of 4 years, one additional revision THA was performed for septic loosening and none for aseptic loosening.Keywords
This publication has 36 references indexed in Scilit:
- Surgical management of recurrent dislocation after total hip arthroplastyOrthopaedics & Traumatology: Surgery & Research, 2014
- Dislocation following total hip replacementThe Bone & Joint Journal, 2013
- Surgical Technique: Transfer of the Anterior Portion of the Gluteus Maximus Muscle for Abductor Deficiency of the HipClinical Orthopaedics and Related Research, 2012
- Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: A 59 cases series with a mean 8 years’ follow-upOrthopaedics & Traumatology: Surgery & Research, 2011
- Use of a Dual Mobility Socket to Manage Total Hip Arthroplasty InstabilityClinical Orthopaedics and Related Research, 2009
- Lumbar Degenerative KyphosisSpine, 2007
- Recurrent Instability after Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2006
- Constrained Acetabular LinersThe Journal of Arthroplasty, 2005
- “Minimally Invasive” Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2005
- Results of Reoperation for Hip DislocationClinical Orthopaedics and Related Research, 2004