Performance Evaluation of Radiation-Shielding Materials and Process Technology for Manufacturing Skin Protection Cream
Author:
Open Access
Abstract
Personnel using X-ray devices, the main source of radiation in medical institutions, are primarily affected by scattered rays. When interventionists use radiation for examinations/treatments, their hands may enter the radiation-generating area. The shielding gloves used for protection against these rays restrict movement and cause discomfort. Here, a shielding cream that directly adheres to the skin was developed and examined as a personal protective device; further, its shielding performance was verified. Bismuth oxide and barium sulfate were selected as shielding materials and comparatively evaluated in terms of thickness, concentration, and energy. With increasing wt% of the shielding material, the protective cream became thicker, resulting in improved protection. Furthermore, the shielding performance improved with increasing mixing temperature. Because the shielding cream is applied to the skin and has a protective effect, it must be stable on the skin and easy to remove. During manufacturing, the bubbles were removed, and the dispersion improved by 5% with increasing stirring speed. During mixing, the temperature increased as the shielding performance increased by 5% in the low-energy region. In terms of the shielding performance, bismuth oxide was superior to barium sulfate by approximately 10%. This study is expected to facilitate the mass production of cream in the future.Keywords
Funding Information
- National Research Foundation of Korea (2020M2C8A1056950)
This publication has 41 references indexed in Scilit:
- Investigation of X-ray permeability of surgical gloves coated with different contrast agentsThe Anatolian Journal of Cardiology, 2015
- Improvement in electromagnetic interference shielding effectiveness of cement composites using carbonaceous nano/micro inertsConstruction and Building Materials, 2015
- Analysis of the enhanced negative correlation between electron density and electron temperature related to earthquakesAnnales Geophysicae, 2015
- Review on the characteristics of radiation detectors for dosimetry and imagingPhysics in Medicine & Biology, 2014
- VOC Contamination in Hospital, from Stationary Sampling of a Large Panel of Compounds, in View of Healthcare Workers and Patients Exposure AssessmentPLOS ONE, 2013
- Lead Contamination of Surgical Gloves by Contact with a Lead HandISRN Orthopedics, 2011
- Color stability of maxillofacial silicone with nanoparticle pigment and opacifier submitted to disinfection and artificial agingJournal of Biomedical Optics, 2011
- Radiation attenuation by lead and nonlead materials used in radiation shielding garmentsMedical Physics, 2007
- Efficacy of protective creams in a modified repeated irritation test: Methodological aspectsActa Dermato-Venereologica, 1998
- Monte Carlo techniques in medical radiation physicsPhysics in Medicine & Biology, 1991