Evaluation of Verisyse and Artiflex phakic intraocular lenses during accommodation using Visante optical coherence tomography
Authors:
- 1 August 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 33 (8) , 1398-1404
Abstract
To perform a dynamic study of the relationship between Verisyse (AMO) and Artiflex (Ophtec B.V.) phakic intraocular lenses (pIOLs) and anterior chamber structures during accommodation using optical coherence tomography (OCT) (Visante, Carl Zeiss Meditec, Inc.) Institutional practice. Eleven myopic patients were randomly selected to have implantation of a Verisyse pIOL in 1 eye and an Artiflex pIOL in the other. Using a 2-dimensional image, dynamic measurements of the relationship between the anterior surface of the pIOL and the corneal endothelium, the posterior surface of the pIOL and the anterior surface of the crystalline lens, and the pupil diameter were performed using Visante OCT. Physiological accommodation was stimulated by adding lenses in 1.00 diopter (D) steps from +1.00 to -7.00 D. Both groups had a significant decrease in pupil diameter (P<.0001, generalized linear model [GLM]) and in the distance between the anterior surface of the pIOL and the corneal endothelium (P<.0001, GLM) with accommodation. There were no statistically significant changes in the distance between the posterior surface of either pIOL and the anterior surface of the crystalline lens (P = .2845, GLM). There were no statistically significant differences between the 2 pIOLs in any measurement (P>.05, GLM). The results fit with Helmholtz' theory of accommodation as forward movement of the diaphragm iris-crystalline lens was seen. There was a decrease in the distance between the pIOL and corneal endothelium and in the pupil diameter, whereas the distance between both pIOLs and the crystalline lens remained constant throughout the accommodation examination. This suggests that the risk for cataract from intermittent contact between the crystalline lens and IOL from accommodative effort is unlikely.Keywords
This publication has 23 references indexed in Scilit:
- Short-term Follow-up after Implantation of a Foldable Iris-Fixated Intraocular Lens in Phakic EyesOphthalmology, 2005
- Secondary Artisan–Verysise aphakic lens implantationJournal of Cataract & Refractive Surgery, 2005
- Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyesJournal of Cataract & Refractive Surgery, 2004
- Effect of methods of myopia correction on visual acuity, contrast sensitivity, and depth of focusJournal of Cataract & Refractive Surgery, 2003
- Artisan toric phakic intraocular lens for the correction of high astigmatismAmerican Journal of Ophthalmology, 2003
- Toric phakic intraocular lensOphthalmology, 2003
- Artisan phakic intraocular lens for myopia Short-term results of a prospective, multicenter studyOphthalmology, 2002
- A randomized paired eye comparison of two techniques for treating moderately high myopia LASIK and artisan phakic lensOphthalmology, 2002
- Adjustable refractive surgery: 6-mm Artisan lens plus laser in situ keratomileusis for the correction of high myopiaOphthalmology, 2001
- Multicenter study of the Artisan phakic intraocular lensJournal of Cataract & Refractive Surgery, 2000