The Inhibition of Lens Epithelial Cell Migration by a Discontinuous Capsular Bend Created by a Band-Shaped Circular Loop or a Capsule-Bending Ring
Authors:
- Okihiro NischiONOkihiro Nischi
- Kayo NishiKNKayo Nishi
- Chizuko ManoCMChizuko Mano
- Masuji IchiharaMIMasuji Ichihara
- Tomoaki HondaTHTomoaki Honda
- 1 February 1998
- journal article
- Published by SLACK, Inc. in Ophthalmic Surgery, Lasers and Imaging Retina
- Vol. 29 (2) , 119-125
Abstract
* BACKGROUND AND OBJECTIVE: This study investigated the inhibitory effect of a discontinuous capsular bend created by an intraocular lens (IOL) with a band-shaped loop or a capsule tension ring on migrating lens epithelial cells (LECs). * MATERIALS AND METHODS: To create a sharp bend in the capsule, the round form (shown on cross section) of the open-circular loop of a polymethylmethacrylate IOL was changed to a band-like shape, 1.0 mm wide and 0.2 mm thick. A capsule tension ring of the same shape (on cross section) with a 14-mm diameter was also made. After cataract surgery, this IOL or ring was implanted into the capsular bag in 5 rabbit eyes. The same IOL with an unmodified haptic or conventional capsule tension ring was implanted in the contralateral eye as a control. After 8 weeks, Miyake view and histopathologic examinations were performed. * RESULTS: LECs accumulated at the equatorial corner outside the haptic or ring, showing the inhibition of LEC migration. In the control eyes, LECs accumulated inside the haptic or ring, forming a Soemmering's ring cataract, thus showing markedly less inhibition of LEC migration on macroscopic and microscopic observations. * CONCLUSIONS: A discontinuous bend in the capsule significantly inhibited LEC migration in rabbit eyes. The creation of a capsular bend through the appropriate design of the IOL-haptic or capsule tension ring might significantly decrease the incidence of posterior capsule opacification for humans. [Ophthalmic Surg Lasers 1998;29:119-125.]Keywords
This publication has 8 references indexed in Scilit:
- Explantation of endocapsular posterior chamber lens after spontaneous posterior dislocationJournal of Cataract & Refractive Surgery, 1996
- Effect of intraocular lens design on posterior capsule opacification after continuous curvilinear capsulorhexisJournal of Cataract & Refractive Surgery, 1995
- Efficacy of Equator Rings in an Experimental Rabbit StudyArchives of Ophthalmology (1950), 1995
- Einsatz des Kapselspannringes im Rahmen von Phakoemulsifikation und Linsenimplantation nach durchgreifender Resektion eines Ziliarkörpertumors1995
- A ring to support the capsular bag after continuous curvilinear capsulorhexisJournal of Cataract & Refractive Surgery, 1994
- Posterior capsule opacificationSurvey of Ophthalmology, 1992
- New posterior chamber lens with open circular haptic for a small capsular opening: Preliminary reportJournal of Cataract & Refractive Surgery, 1990